Descargar Imprimir esta página

Technical Data; General Data And Operating Conditions - Lenze E84DGDVB3714 Instrucciones Para El Montaje

Ocultar thumbs Ver también para E84DGDVB3714:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3

Technical data

General data and operating conditions

3
Technical data
3.1
General data and operating conditions
Conformity and approval
Conformity
CE
Approval
UR
UR
C
Protection of persons and equipment
Enclosure
(Earth) leakage
current
Total fault current
Motor mounting
Wall mounting
additional
equipotential bonding
Protective insulation
of control circuits
Insulation resistance
34
All manuals and user guides at all-guides.com
2006/95/EG
UL 508C
C22.2 No 14
EN 60529
NEMA 250
EN 61800−5−1
EN 61800−5−1
EN 61800−5−1
Low−Voltage Directive
Power Conversion
Equipment, File No.
E170350
IP55, IP65
optional: IP66
Protection according to
Type 4
l
Type 12
l
– Not with plug−in
modules or brake
resistor modules.
> 3.5 mA AC,
> 10 mA DC
The following earth−leakage circuit breakers may be
used in TN systems:
E84DGDVB3714
...
E84DGDVB1524
E84DGDVB2224
E84DGDVB3024
E84DGDVB3714
...
E84DGDVB3024
M5 thread with terminal in the WU for connection of
a 16mm@ PE cable
Safe isolation from mains by double (reinforced)
insulation
Site altitude
0 ... 2000 m Overvoltage category III
2000 ... 4000 m Overvoltage category II
l
EDK84DGDVBxxx4 DE/EN/FR/ES/IT 3.1
Still in preparation for:
E84DGDVB2224
E84DGDVB3024
in ready−for−use state:
Close unused bores for
l
cable glands with
blanking plugs!
Close unused connectors
l
with protection covers or
blanking plugs!
Observe the regulations and
safety instructions!
30 mA, type B
300 mA, type B
300 mA, type B

Publicidad

loading