7
Commissioning
7
Commissioning
Preconditions for initial switch−on
The Wiring Unit is mounted and wired according to the instructions,
ƒ
–
directly on a motor clamping flange, or
–
with the wall adapter on a suitable surface near the motor.
Connections with the mains, motor, holding brakes, etc, have been
ƒ
established.
The Communication Unit was mounted and wired according to the
ƒ
planned application.
–
Input and output signals
–
Safe input
–
Fieldbus
(depending on the design, only available optionally)
If required, the basic settings for "Local mode" were carried out.
ƒ
–
DIP switches
–
Potentiometer
The Drive Unit was mounted and wired.
ƒ
Use available control functions reasonably, e.g.
ƒ
–
Inhibit controller enable
–
Set speed setting to minimum
–
Activate safety device
}
Danger!
High hazard potential during commissioning
Incorrect settings can cause unexpected and dangerous movements
of the motor and the equipment.
Possible consequences:
ƒ
ƒ
Protective measures:
ƒ
ƒ
48
All manuals and user guides at all-guides.com
Damage to material assets
Injury to persons
Clear hazard area
Observe safety instructions and safety distances
l
EDK84DGDVBxxx4 DE/EN/FR/ES/IT 3.1