REPAIRS
If any problems are found with the original parts during mantel assembly, such as that
the panels cannot be installed with the plastic connectors, try to solve by one of the
following methods.
Tools required: Electric drill, drill bit 10 mm (3/4 in) or 2 mm (1/16 in), pencil, hammer,
Phillips screwdriver, safety goggles and gloves (if necessary).
warNiNG: wEar GOGGlES BEFOrE yOU Start DrilliNG.
OptiON 1:
Use the spare nuts, screws and plastic connector.
1. Place the plastic connector on the mantel unit and mark the drill holes,
as shown in Fig. A.
2. Drill holes with diameter 10 mm (3/4 in) and depth 10 mm (3/4 in) on the mantel. Each
plastic connector needs 3 holes. See Fig.B.
Fig. B
3. Gently install the nuts into the drilled holes with a hammer, as shown in Fig. C.
4. Attach the plastic connector and lock in place with the screw, as shown in Fig. D.
All manuals and user guides at all-guides.com
Fig. A
Fig. C
Back
Fig. D
OptiON 2:
Use the small L-brackets and screws.
1. Place the small L-bracket on the unit, as shown, and mark the drill holes on the mantel,
as shown in Fig. E.
2. Drill holes with diameter 2 mm (1/16 in) and depth 8 mm (5/16 in) on the mantel. Each
small L-bracket needs 4 holes. See Fig. F.
Fig. F
3. Attach the small L-bracket and lock in place with screws, as shown in Fig. G.
CLEANING
To clean the unit, first turn off the controls on the unit and unplug the unit from the power
source. To clean the glass display panel: remove dust with a clean, dry cloth or remove
fingerprints and other marks with a clean, damp cloth. Do not use abrasive cleaners or
spray liquids on the glass display. Metal and metal painted parts should be cleaned with
a damp cloth. Do not use abrasive cleaners or spray liquids on these surfaces.
8