Hart VP205-C-3701 Manual Del Operador página 12

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE
INSTALLING REUSABLE CLOTH FILTER
See Figures 34-36.
• Verify that the power cord is disconnected from
the outlet.
• Remove the power head and place in an upside-
down position.
• Install the reusable cloth filter over the filter cage
making sure the cage is completely covered.
• Place the power head back onto the collection
tank.
FIG. 34
FIG. 35
FIG. 36
REMOVING & CLEANING REUSABLE CLOTH
FILTER
See Figures 37-38.
• Remove the power head and place in an upside-
down position.
• Clean the reusable cloth filter by gently brushing
or rinsing off the debris. Cleaning should not
be done indoors in living areas. For optimal
performance a new filter is recommended.
• Allow the wet filter to air dry for 24 hours before
installing onto the filter cage.
FIG. 37
FIG. 38
12 English