Battery charging indicator during operation:
v Push the button
y
on the battery.
66 – 99 % charged
«
,
∑
and
€
33 – 65 % charged
and
illuminate
«
∑
10 – 32 % charged
illuminates
«
0 – 10 % charged
«
flashes
3. MAINTENANCE
Make sure that the surface and the contacts of the battery and the battery charger
always are clean and dry before you connect the battery charger.
Do not use running water.
v Clean the contacts with a soft and dry cloth.
4. STORAGE
To put into storage:
The product must be stored away from children.
1. Charge the battery.
2. Store the battery in a dry, moisture-free and frost-free place.
Disposal of the battery:
The GARDENA battery contains lithium-ion cells that should not be disposed
of with normal household waste at the end of its life.
Li-ion
Important!
Dispose of the batteries through or via your municipal recycling collection centre.
1. Discharge the lithium-ion cells completely (contact the GARDENA Service).
2. Protect the contacts on the lithium-ion cells against short circuits.
3. Dispose of the lithium-ion cells properly.
5. TROUBLESHOOTING
Error messages of the error-LED
Problem
Possible Cause
Error-LED
¥
on the battery
Under voltage.
flashes
Battery temperature is out of
range.
All manuals and user guides at all-guides.com
illuminate
¥
/
≈
(see page 3).
Remedy
v Charge the battery.
v Use the battery in surroun-
dings where temperatures are
between – 10 °C and 40 °C.
Problem
Possible Cause
Error-LED
¥
on the battery
Battery error / battery defective. v Contact the GARDENA
illuminates
Charging control lamp
å
on the
Battery charger or charging cable
charger does not illuminate
are not connected correctly.
Battery temperature is out of
Charging control lamp
å
on
the charger flashes rapidly
range.
(4 times per second)
Battery error.
Error-LED
≈
on the charger
flashes
Error-LED
≈
on the charger
Temperature inside the charger
illuminates
is too high.
NOTE: For any other malfunctions please contact the GARDENA service department. Repairs must
only be done by GARDENA service departments or specialist dealers approved by GARDENA.
6. TECHNICAL DATA
System Battery BLi-40
Unit
Value (Art. 9842)
Max. Battery voltage
V (AC)
40 *
Battery capacity
Ah
2.6
Battery charging time
min.
65 / 90
80 % / 100 % (approx.)
* The maximum initial no-load voltage of the battery is 40 V, the nominal voltage is 36 V.
7. SERVICE / WARRANTY
Service:
Please contact the address on the back page.
Warranty:
In the event of a warranty claim, no charge is levied to you for the services provided.
GARDENA Manufacturing GmbH offers a two-year warranty (effective as of the date
of purchase) for this product. This warranty includes all significant defects of the
product that can be proved to be material or manufacturing faults.
For Art. 9842: This warranty is fulfilled by supplying a fully functional replacement
product or by repairing the faulty product sent to us free of charge; we reserve the
right to choose between these options. This service is subject to the following provi-
sions:
For Art. 9843: The warranty will be fulfilled by the supply of a working replacement
product provided that the following conditions are met:
Remedy
Service.
v Connect the battery charger
and charging cable correctly.
v Use the battery in surroun-
dings where temperatures are
between – 10 °C and 40 °C.
v Remove the battery and
check that you use an original
GARDENA battery.
v Contact the GARDENA
service.
Value (Art. 9843)
40 *
4.2
105 / 140
9