Truma SecuMotion Instrucciones De Uso página 16

Ocultar thumbs Ver también para SecuMotion:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
Installing and connecting
the gas pressure
regulation system
The gas pressure regulation
system must be installed so that
the gas pressure regulation sys-
tem inlet is at least at cylinder
valve height.
Positioning SecuMotion
above the cylinder valve
helps prevent gas in the liquid
phase from entering the low
pressure area, especially when
driving. The use of 10 mm di-
ameter gas pipes will improve
the performance of all attached
devices. When using outdoors,
use a protective hood or similar
16
device to protect the gas pres-
sure regulation system from the
elements.
– Attach high pressure hose (on-
ly with hose rupture protection
device!) to the gas pressure
regulation system inlet, using
an angle union (a) if necessary
(see "Accessories").
a
– Choose a suitable position for
the gas pressure regulation
system, in particular: the type
plate is visible, the gas-flow
monitor's button is visible and
easily accessible, avoid dam-
age when changing cylinders,
thwart penetration by gas in
the liquid phase, plan for a
place to retrofit DuoComfort,
avoid tension in the high pres-
sure hose.
95 mm
– Attach gas pressure regulation
system to the wall with two
screws.
– Connect the 8 mm or 10 mm
gas supply pipe to the gas
pressure regulation system
outlet according to the respec-
tive installation instructions
for cutting-ring screw fittings.

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido