Technical Data - Hansgrohe Talis C 33147000 Instrucción De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
Assembly
Attention! The fitting must be installed, flushed and
tested after the valid norms.
Operation
The mixer is actuated by lifting the lever head.
Move to the left = hot water, move to the right =
cold water.
The flow is changed from bath to shower function
by pulling the knop at the upper side of the spout.
After shutting off the water flow, the mixer returns
automatically to the bath function.

Technical Data

Operating pressure:
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.: 65° C
Rate of flow 0,3 MPa:
33148000 / 33147000:
Outlet Bath tubv approx. 30 l/min
Outlet Shower
33166000:
33148000 Back flow and vacuum breaker.
Hansgrohe single lever mixers can be used toge-
ther with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0,15 MPa.
Fault
Mixer stiff
Mixer dripping
Diverter not operating
Hot water temperature too low,
no cold water.
Instantaneous water heater starts
up when cold water is selected.
English
max. 1 MPa
1,6 MPa
max. 80° C
approx. 24 l/min
approx. 32 l/min
Cause
Cartridge defective, calcified
Cartridge defective, sedimenta-
tion
Water pressure to low
Diverter defective
Hot water limiter incorrectly set
Crossflow
To adjust the hot water limiter on single lever mixers,
please see page 14.
Don't install a hot-water-barrier in combination with
flow-heater!
Install the ibox always above the bath-tup. If parts of
the ibox will broken, the water can flow in there!
148000: The safety device of 33148000 must
be checked once a year.
The non return valves must be checked regularly ac-
cording to DIN EN 1717 in accordance with national
or regional regulations (at least once a year).
Spare parts (see page 3)
1
handle Talis C
1.1 screw cover
2
face plate
3
face plate
4
flange
5
fixing screw (4)
6
sub plate
7
nut
8
locking screw for handle
9
non return valve
10
noise reduction
11
selector assy
12
cartridge cpl.
13
sleeve
14
diverter knob
15
extension set 25 mm
Remedy
Exchange cartridge
Exchange cartridge
Increase water pressure
Exchange diverter
Set hot water limiter
Exchange cartridge
33092000
94186000
96453000
96452000
95010000
96454000
96447000
95007000
96059000
96655000
94073000
95014000
92730000
96448000
13471000
13595000
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Talis c 33148000Talis c 33166000

Tabla de contenido