Installation

The roof air conditioner may only be installed by qualified personnel from a
specialist company. The following information is intended for specialists
who are familiar with the guidelines and safety precautions to be applied.
5.1

Installation instructions

These installation instructions must be read completely prior to the
installation of the roof air conditioner.
The following tips and instructions must be observed during the installation
of the roof air conditioner:
Interrupt all power supplies when working on the roof air conditioner.
Only for EC-1500-AC/DC and EC-2000-AC/DC:
Make sure the inverter is also switched off and the power supply is
interrupted.
You should always check whether any vehicle components (e.g. lamps,
cabinets, doors etc.) could be damaged by installing the roof air
conditioner before doing so.
Prior to the installation you should find out (by consulting the
manufacturer of the vehicle) whether the construction is designed for
the static weight and the loads of the air conditioner when the vehicle is
in motion. The manufacturer of the roof air conditioner (WAECO)
assumes no liability whatsoever.
The vehicle manufacturer may have already provided points where the
opening for the installation of the roof air conditioner can be applied
without any risk of weakening the construction or cutting power cables.
Select a flat and sufficiently level area at the centre of the roof of the
vehicle as installation location.
Make sure no combustible objects are stored or installed within the air
outlet area. A distance of at least 50 cm should be kept.
Make sure that there are no objects within the vehicle which could
obstruct the attachment of the air distribution unit or prevent the cooled
and heated air escaping from the swivelling air distribution nozzles.
Observe, for safety reasons, the location of existing cable strands,
lines and other components within the installation area, in particular
those which are not visible, when installing the roof air conditioner
(when drilling or screwing etc.).