5) LOCAL COMMANDS Fig. C
Pressing the S3 key commands one START. By pressing the key again while the
automated device is moving a STOP is commanded.
6) SAFETY DEVICES
Note: only use receiving safety devices with free changeover contact.
6.1) TESTED DEVICES Fig. H
6.2) CONNECTION OF 1 PAIR OF NON-TESTED PHOTOCELLS Fig. D
7) MEMORIZING TRANSMITTERS FIG. E
RADIO
-
IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE
IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).
in the event of manual programming, the first transmitter assigns the RECEiVER'S
KEY CODE: this code is required to subsequently clone the radio transmitters. The
Clonix built-in on-board receiver also has a number of important advanced features:
•
Cloning of master transmitter (rolling code or fixed code).
•
Cloning to replace transmitters already entered in receiver.
To use these advanced features, refeXr to the universal handheld programmer's
instructions and to the general receiver programming guide.
8) AUTOSET ADJUSTMENT FIG. F
Enables Motor Torque to be set automatically.
if the power is suddenly disconnected and then restored the automation performs
the operations at autoset speed till the travel limits are identified.
WARNING!! The autoset operation must be performed only once you have che-
cked that the leaf is moving accurately (opening/closing) and that the mechanical
stops are positioned correctly. You must run an autoset cycle whenever the motor
force (T2), the slow-down distance (T3) .
WARNING! While the autoset function is running, the obstacle detection function
is not active. Consequently, the installer must monitor the automated device's
movements and keep people and property out of range of the automated device.
WARNING: the torque values set by the autoset function refer to the motor force
set during the autoset cycle. if motor force is edited, an autoset opening and
closing cycle will need to be performed again.
WARNING: check that the force of impact measured at the points provided for
by standard EN 12445 is lower than the value laid down by standard EN 12453.
Setting sensitivity incorrectly can result in damage to property and injury to
people and animals.
SOLENOID LOCK
WARNING: In the case of leaves longer than 3m, it is essential to install
a solenoid lock.
KEYS
KEYS
Description
Add Start Key
S1
associates the desired key with the Start command.
Add Pedestrian Key
S2
associates the desired key with the pedestrian command.
S2
Confirms the changes made to parameter settings and operating
>5s
Erase List
S1+S2
WARNING! Erases all memorized transmitters from the
>10s
receiver's memory.
Pressed BRiEFLY, it gives the START command.
S3
HELD DOWN (>5 sec.), it activates the AUTOSET function.
LED INDICATORS:
POWER
Steadily lit: - Mains power on - Board powered - Fuse F1 intact
START
Lit: START input activated
OPEN
Lit: OPEN pedestrian input activated
STOP
Unlit: STOP input activated
PHOT
Unlit: PHOT photocell input activated
FAULT 1 PHOT input safety device test input diagnostics
BAR
Unlit: BAR safety edge input activated
FAULT 2 BAR input safety device test input diagnostics
Lit: the limitswitch closing of motor 1 is free
SWC1
Unlit: motor 1 closing limit switch input activated
Lit: the limitswitch opening of motor 1 is free
SWO1
Unlit: motor 1 opening limit switch input activated
Lit: the limitswitch closing of motor 2 is free
SWC2
Unlit: motor 2 closing limit switch input activated
Lit: the limitswitch opening of motor 2 is free
SWO2
Unlit: motor 2 opening limit switch input activated
Unlit: no error
ERR
LiT: see error diagnostics table
All manuals and user guides at all-guides.com
INSTALLATION MANUAL
RADIO
(GREEN)
9) ADJUSTMENT PROCEDURE
- Before turning the unit on, check electrical connections.
- Set the following parameters: Automatic Closing Time, motor force, slow-down
- Set the logics.
- Run the autoset function.
WARNING! Incorrect settings can result in damage to property and injury
to people and animals.
by standard EN 12453.
For best results, it is advisable to run the autoset function with the motors idle (i.e.
10) INSTALLATION TEST PROCEDURE
1. Run the AUTOSET cycle (*)
2. Check the impact forces: if they fall within the limits (**) skip to point 9 of the
3. Where necessary, adjust the sensitivity (force) parameter: see parameters table.
4. Check the impact forces again: if they fall within the limits (**) skip to point 9
5. Apply a shock absorber profile
6. Check the impact forces again: if they fall within the limits (**) skip to point 9
7. Apply pressure-sensitive or electro-sensitive protective devices (such as a
8. Check the impact forces again: if they fall within the limits (**) skip to point 9
9. Make sure all devices designed to detect obstacles within the system's operating
(*) Before running the autoset function, make sure you have performed all the
(**)Based on the risk analysis, you may find it necessary to apply sensitive protective
WARNING! Incorrect settings can result in damage to property and injury
to people and animals.
LED ERR:
Unlit: remote programming not active
Radio LED only flashing: Remote programming active, waiting for
hidden key.
Flashing in sync with Set LED: Transmitter deletion in progress
Lit: remote programming active, waiting for desired key.
Lit 1s: Radio receiver channel activated
Lit: Set key pressed / Autoset completed successfully
Flashes three times: Autoset in progress
Fast flashing 10s: Autoset failed
SET
Flashing in sync with Radio LED: Transmitter deletion in progress
Lit 1s: Start/Stop after key S3 pressed
Lit 10s: Autoset completed correctly
distance.
WARNING: Check that the force of impact measured at the points
provided for by standard EN 12445 is lower than the value laid down
not overheated by a considerable number of consecutive operations)
procedure, otherwise
of the procedure, otherwise
of the procedure, otherwise
safety edge) (**)
of the procedure, otherwise
range are working properly
assembly and make-safe operations correctly, as set out in the installation
warnings in the drive's manual.
devices anyway
Led SET
Lit
Photocell test,
Reverse due to
Costa o Costa 8k2
obstacle - Ampe-
failed
rostop
Unlit:
- Check photocell
- Check for obsta-
connection and/or
cles in path
logic settings
internal system
supervision control
error.
- Try switching the
board off and back
Lit
on again.
if the problem
persists, contact
the technical
assistance de-
partment.
Photocell test failed
slow
- Check photocell
flashing
connection and/or
logic settings
Led ERR
slow flashing
fast flashing
Thermal cutout
- Allow automated
device to cool
Limit switch error
- Check limit
switch connections
Parameters
and/
or Operating Logic
edited
- if the "Slow-down
distance" is edited,
run a new Autoset
cycle to confirm
the new setting.
- if other parame-
ters and/or opera-
ting logic are edi-
ted, hold down S2
for 5s to confirm.
NOTE: in any case,
the Autoset fun-
ction confirms all
changes made to
the board.
- 11
ZARA BTL2