TABLE "A" - PARAMETERS
TRIMMER
Parameter
Automatic
T1
closing time [s]
T2
Leaf force [%]
Slow-down
T3
distance [%]
Motor 1 closing
T4
delay time [s]
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
TABLE "B" - LOGICS
DIP
Logic
Default
Transmitter
1
programming
2
BAR / 8K2
Photocell input
3
check
4
Edge input check
Photocells
5
during closing
6
Fast closing
Block pulses
7
during opening
8
3-step logic
Hammer during
9
opening
Closing limit
10
switch pressure
12
- ZARA BTL2
All manuals and user guides at all-guides.com
INSTALLATION MANUAL
+
+
min.
max.
Waiting time before automatic closing.
0
120
NOTE: Set to 0 if not used.
Force exerted by leaf/leaves.This is the percentage of force delivered, beyond the force stored during the
autoset cycle (and subsequently updated), before an obstacle alarm is generated.
10
100
WARNING: It affects impact force directly: make sure that current safety requirements are met
with the set value (*). Install anti-crush safety devices where necessary.
Set slow-down speed as a percentage of total travel. This distance is travelled at low speed.
5
50
NOTE: When this parameter is edited, a new Autoset cycle must be run to confirm it.
Motor 1 closing delay time with respect to motor 2.
0
25
NOTE: set 0 for single motor operations (leaf 1).
Cross out
Description
setting used
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has
already been memorized in standard mode via the radio menu.
2- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be
ON
memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new
transmitters.
ON
This mode does not require access to the control panel.
iMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
Disables wireless memorizing of transmitters and automatic addition of clones.
Transmitters are memorized only using the relevant Radio menu or automatically with re-
OFF
plays.
iMPORTANT: Disables the automatic addition of new transmitters and clones
input configured as Bar 8k2 (Fig.H, ref.5). input for resistive edge 8K2.
ON
The command reverses movement for 2 sec.
OFF
input configured as Bar, safety edge (Fig.H, ref.3-4).
OFF
The command reverses movement for 2 sec..
ON
Enable safety check on the PHOT input
OFF
OFF
Safety check on PHOT input not enabled
ON
Enable safety check on the BAR input
OFF
OFF
Safety check on BAR input not enabled
in the event beam is broken, photocell operation is disabled during opening. During closing,
ON
movement is reversed immediately.
OFF
When beam is broken, photocells are active during both opening and clo-
OFF
sing. When beam is broken during closing, movement is reversed only once the
photocell is cleared.
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
ON
OFF
OFF
Logic not enabled
ON
The start pulse has no effect during opening.
OFF
OFF
The start pulse has effect during opening.
Switches to 3-step logic; during closing,
ON
start reverses movement.
OFF
OFF
Switches to 4-step logic.
OFF
Logic not enabled
OFF
Before opening completely, the gate pushes for approx. 2 seconds as it closes. This allows
ON
the solenoid lock to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
Movement is stopped only when the closing limit switch trips: in this case, the tripping of
OFF
the closing limit switch must be adjusted accurately (Fig.G Ref.B).
Use when there is a mechanical stop in closed position.
OFF
This function allows leaves to press against the mechanical stop without the Amperostop
sensor interpreting this as an obstacle.
ON
Thus the rod continues its stroke for a few seconds after meeting the closing limit switch or
as far as the mechanical stop. in this way, the leaves come to rest perfectly against the stop
by allowing the closing limit switches to trip slightly earlier (Fig.G Ref.A).
Description
CLOSED
DURiNG CLOSiNG
OPEN
DURiNG OPENiNG
AFTER STOP
3 step
4 step
opens
opens
stop
closes
closes
stop +
stop +
TCA
TCA
opens
opens