• Do not wind the cord around the device! Do not
operate the device with the cord wound up!
• Do not clamp the cord, or pull it over sharp edges!
• Do not run cord under carpeting, throw rugs or runners
etc. Arrange cord away from areas where it is likely to be
tripped over.
•Never use the appliance if the appliance or cord is
damaged. Risk of injury!
I
:
NSTALLATION
• The device may only be installed and connected by
qualified professionals. The installation must be
isolated prior to commencing any electrical work!
Risk of fire!
• Sufficient air exchange for heat dissipation must
be ensured in the cavity above the radiant heater.
• Only commission the device after it has been fully
installed.
• This heater comes with a pair of stainless steel adjustable
angle mounting brackets. The adjustable angle enables the
heater to be installed on vertical, horizontal and inclined
surfaces.
WARNING:
Slight crackles may be heard during the heating or cooling
period. This is normal operational noise.
NOTE:
After switching on the appliance for the first time and
following extended periods on non-use, the appliance
may expel a slight odor for a short time. It will not
affect the use of the heater.
To exclude unpleasant burnt odor, it is recommended
to keep the heater clean preventing accumulation of
dust on it
The distance between the heater and the remote cont
rol should be less than 3 metre, and the remote contr
ol must be directly point to the receiver on the front p
anel during the operation.
I
NSTALLATION REGARDING THE MODEL
In case of direct connection to the supply line, a bipolar
switch or a bipolar circuit breaker with contact opening
distance of at least 3mm must be fitted upstream from the
supply line. Contact an authorized service technician if you
are unsure if you have a switch or a circuit breaker installed
on the premises.
Plug in the device in the socket of main power, the
heater starts heating.
Unplug the device from the socket or press the switch
or the circuit break to power off the device.
C
:
LEANING
• First, disconnect the equipment from the power supply
system!
• After the appliance has cooled down, wipe off dust with a
damp soft rag in cold condition
• During operation, it is necessary to periodically (once a
year) check the electric cable contacts and terminal
connectors for good tightening.
• Do not use any abrasive or caustic cleaning agents!
• Never immerse the appliance in water! Danger to life!
BRELG1200-1:
A
-S
S
:
FTER
ALES
ERVICE
• All repairs must be referred to authorised personnel!
Therefore, you should contact your specialized dealer or
the customer service.
• Important! Any tampering with the appliance will
invalidate the warranty.
• Repairs carried out improperly and by unqualified persons
may have serious consequences for the user!
T
D
:
ECHNICAL
ATA
• Connection/fuse: 230/240 Volt (50/60 Hz) with 16 Amp B
or C (= slow-blowing fuse)
• Output: 1200 Watt, 1500 Watt, 1800 Watt und 2200 Watt
• Infrared tube: 1,2 kW= BRELGR1200, 1,5 kW=
BRELGR1500, 1,8 kW= BRELGR1800, 2,2 kW= BRELGR2200,
• Guaranteed service life: up to 5000 hours with average
use
• Type of protection: IP65
• Weight BRELG2200-x models: 5,1 kg
• Weight BRELG1200-3 model: 3,5 kg
• Weight BRELG2200RD-x models: 5,2 kg
• Weight BRELG1200R-3 model: 3,6 kg
• Casing: Corrosion-resistance anodized aluminium
• Front: SCHOTT NEXTREMA® ceramic glass
• Cable: 1,80m 3-wire 1,5 mm², Schuko plug
O
I
PERATING
NSTRUCTION FOR
1. Ceramic glass panel
2. Power cords and plug
3. Brackets for wall or ceiling mounting
4. Remote control (only for models BIGH1200R-x)
1
O
I
PERATING
NSTRUCTION FOR
:
MODELS
1. Ceramic glass panel
2. ON/OFF main power switch
3. Power cords and plug
4. Brackets for wall or ceiling mounting
5. Remote control (only for models BRELG1500Rx,
BRELG1800Rx and BRELG2200Rx)
BRELG1200
:
X MODELS
3
2
4
3
2
BRELG1500
- BRELG2200
X
X
GB