Installation Procedure - Franke OPERA POC 6 3GAV-D-O Manual De Instalación Y Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
POC 6 3GAV-D-O / POI 6 3GAV-D-O / POL 6 3GAV-D-O / POT 6 3GAV-D-O
POC 6 3GAV-D-O / POI 6 3GAV-D-O / POL 6 3GAV-D-O / POT 6 3GAV-D-O
20 mm

Installation procedure

The appliance is fixed to the unit by means of
the brackets and accessories provided.
Z
X
Make sure that there is free access to the
fixing elements in front and in the rear
after the installation of the appliance.
Z
X
Prepare the hole in the worktop according
to the dimensions indicated. Be sure to
comply with the dimensions indicated.
Yp
Xtop
Htop
Models
POI/POL/POC 6 3GAV-D-O
Legend
POI
Satin-finish stainless steel Opera hob
POL
Dekor stainless steel Opera hob
POC
Coloured Opera hob
G
Gas
A
Electronic ignition
V
Safety valve
D
Dual Burner
X
X
X
Connection to gas supply
X
Z
Xp
Connection to the gas supply can be made
in two ways:
X
Ytop
X
IMPORTANT: if a stainless steel hose is used, it
must be installed so as not to touch any mobile
part of the furniture. It must pass through an
area where there are no obstructions and where
it is possible to inspect it on all its length.
X
X
– 9 –
X
Apply the sealing strip around he hole
and position the hob.
X
Fix the appliance with the screws
and brackets.
X
Remove any excess sealing strip.
X
Connect the appliance to the gas supply
in compliance with the current regulations,
only after making sure it is arranged for the
type of gas to be used. Otherwise, carry out
the operations described in the paragraph
„Replacing injectors".
X
For liquid gas use pressure regulators
complying with the current regulations.
X
A. Connect the gas hob using a 12 mm
diameter rigid copper pipe (3). To ensure
a good seal, use the elastomer gasket
supplied as an accessory (1).
X
B. Connect the hob using a continuous-
surface flexible steel tube (2). Also in this
case, to ensure a good seal use the gasket
supplied as an accessory (1). The maximum
length of the hose is 2 linear metres.
X
After connection to the gas supply light up
the burners and turn the knobs from max
position to minimum position to check
flame stability.
X
After carrying out the connection use soapy
water to check for any leaks.
EN