4.5) Alarms/Warnings
These appear on the display during operation and inform the operator on the state of the tool.
Message
BATTERY
BATTERY
TEMPERATURE
30001
MAINTENANCE
4.6) ERRORS:
these appear during operation, combined with a beep and fl ashing LED Worklights,
to notify the operator of procedural or operational errors.
Message
The pressure release button (6) was
pressed before the control parameters
ERROR
were reached (Force/Pressure).
Abnormal power consumption of the
motor for more than 3 seconds.
001
The tool stops.
Output voltage of the pressure trans-
002
mitter is out of the pre-set range.
Failure to reach the set pressure within
003
30 seconds continuous operation of
the tool.
Overcharging of the battery with
protection tripping.
004
The tool stops.
Error screens are displayed for about 30 seconds before being reset, but will display repeat-
edly in the event of permanent anomalies.
Meaning
Replace or recharge the battery.
BATTERY
NOTE: when the battery voltage falls below a minimum safety
LOW
threshold, the tool will not start, although it is still possible to
end the work cycle in progress.
Remove the battery and wait until it cools down.
BATTERY
In order to cool quicker, it is possible to insert it into the supplied
battery charger supplied, thus making use of the specifi c "AIR
HIGH
COOLED" function.
No. of cycles to recommended maintenance is reached. The tool
continues to work however, it is recommended that it is sent to
REQUEST
Cembre for a complete overhaul (Ref. to section 7).
NOTE: this message, will reappear when the tool has been idle
for 30 s.
Error description
Description
Solution
Repeat the work cycle and wait for the
motor to stop automatically.
Wait for the display to turn off (60 sec.)
or remove and re-insert the battery, then
re-start the tool.
If the error occurs frequently, contact
Cembre.
Repeat the work cycle; if the error occurs
frequently, contact Cembre.
Repeat the work cycle; if the error occurs
frequently, contact Cembre.
Wait for the display to turn off (60 sec.)
or remove and re-insert the battery, then
re-start the tool.
If the error occurs frequently, contact
Cembre.
12