14.
4. NORMAL USE OF THE STOVE
4.1 DISPLAY INFORMATION
Button 1:
Button 2:
Button 3:
Receiver 4:
LED 5:
LED 6:
LED 7:
4
LED 8:
74
levels is higher than 220ºC, the stove must be reset at the level in question
by reducing the pellet feed in conjunction with the speed of the flue gas
blower and/or increasing the speed of the room blower.
Having the stove commissioned by an approved Qlima technician carries
the following benefits:
• There will be less soot build-up so the flue and the stove will stay
cleaner for longer.
• The stove will consume less fuel.
• The stove will work at optimum efficiency.
• The stove's components will be put under less stress, which will extend
its life.
• The stove will require fewer services and less maintenance.
Once set, the stove is ready for use.
The ash drawer and brazier must be cleaned before every start-up. See
section 6.4. In addition, the stove door must be closed.
The stove may not be used in conjunction with an air extractor system,
hot air heating or other appliances that have an effect on the air
pressure in the room. Such appliances must be switched off when the
pellet-burning stove is in use.
Lowers the room temperature desired by the user. Button 1 can also
be used to show and alter the level of heat output.
Raises
the
room
Button 2 can also be used to show and alter the level of heat output.
Is used to turn the stove on and off.
Remote control receiver.
Indicates an Alarm C (C stands for temperature) error. For more in-
formation, see section 8.2 "error list".
The stove features a clock for setting the start-up and switch-off
times. When this LED is lit, the clock mode is active.
Indicates that the set temperature has been reached. The text ECO
and the set temperature will also be shown on the display.
Indicates that the pellet feed auger is active.
temperature
desired
by
the
user.