Qlima ECO 1700 Instrucciones De Uso página 86

Ocultar thumbs Ver también para ECO 1700:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

15 minutes
after start-
ing, the stove
displays the
"ALARM / FAN
/ ACC" alert
Wooden pel-
lets are not
reaching the
combustion
chamber
The fire has a
weak, or-
ange flame,
pellets are
not burning
properly and/
or the glass
becomes black
too quickly.
Room air recir-
culation blow-
er continues to
run when the
stove is cold.
4
86
The ignition mechanism
is defective.
The temperature sen-
sor has not detected the
minimum temperature
threshold to initiate
start-up
Outdoor temperature is
too low.
Wooden pellets are damp
Temperature sensor is
defective
Electronic printed circuit
board is defective
The hopper is empty
Auger is blocked
Auger motor is damaged
The hopper is empty
The exhaust/flue/chimney
is blocked
The brazier is dirty
There are internal ob-
structions in the stove.
Smoke extractor is dam-
aged.
Wooden pellets are not
of a good quality.
The stove has not been
set up properly.
Electronic printed circuit
board is defective.
Replace the ignition mechanism. Only to
be done by a Qlima-approved technician
Empty the combustion chamber and start
again if the problem recurs. Contact a
Qlima-approved technician if the problem
persists.
Empty the combustion chamber and start
again. Contact a Qlima-approved techni-
cian if the problem persists.
Only use fry wooden pellets.
Replace the sensor. Only to be done by a
Qlima-approved technician
Replace the electronic printed circuit
board. Only to be done by a Qlima-ap-
proved technician
Fill the pellet hopper.
Unplug the stove at the mains socket.
Remove the protective grill from the hop-
per and clean the hopper. Carefully clean
the visible parts of the auger. Refit the
protective grille and start again. Contact a
Qlima-approved technician if the problem
persists.
Replace the motor. Only to be done by a
Qlima-approved technician
Fill the pellet hopper.
Have the exhaust/flue/chimney cleaned im-
mediately by an approved chimney sweep.
Contact an approved chimney sweep.
Clean the brazier
The stove requires maintenance. Only to
be done by a Qlima-approved technician
Wooden pellets are able to burn thanks
to the natural draw of the flue. Have the
blower replaced immediately as it can be
detrimental to your health. Only to be
done by a Qlima-approved technician.
Try better quality pellets
Set up the stove. Only to be done by a
Qlima-approved technician
Replace the printed circuit board Only to
be done by a Qlima-approved technician

Publicidad

Tabla de contenido
loading

Tabla de contenido