Installation and connection of the hydraulic unit
Fix the hydraulic unit to the front left column.
Then create the hydraulic connection to the cylinder by means of the hydraulic hose and
leakage oil line.
Fill hydraulic oil up to the mark on the dipstick.
You will find the associated circuit diagram in Appendix 6.3 of these operating instructions.
Create pneumatic connection
Connect the electromagnetic pneumatic valve, which is located in the front crossbeam, to the
compressed air line. This valve controls the pneumatic cylinders for unlocking the safety catches.
You will find the associated circuit diagram in Appendix 6.1 of these operating instructions.
Installation and connection of the electrical control
Fix the electrical control to the front left column.
Guide all of the cables through the screw connections in the control box
and connect them in accordance with the diagram.
You will find the associated circuit diagram in Appendix 6.2 of these operating instructions.
® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2020-03