The horizontal position can be adjusted by tightening
or loosening
the fixing nuts for the lifting cables (02).
After this, raise and then lower the lift completely. Check the synchronisation while doing so. This may
have to be readjusted if necessary.
To check synchronisation, you can listen to the clicks of the safety catches.
A readjustment of the lifting cables after a short period of operation may be necessary because of
the material used and is not a matter covered by the warranty but a maintenance task for which the
user is responsible.
- Completely lower the lift and continue to hold the
LOWER button for approx. 15 seconds to bleed the hydraulic system completely.
- Now fit the missing components (e.g. access ramps, roll protection, column
covers etc.)
After the set-up process, fill in the attached inspection log.
This information is needed if there is a service case
® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2020-03
All manuals and user guides at all-guides.com
Manufacturer ATH-Heinl GmbH & CO.KG
- 27 -
The horizontal position can be adjusted by tightening
or loosening
the fixing nuts for the catch bar (01).
.