Direct Current
Range
Resolution
1 µA
2 mA
10 µA
20 mA
100 µA
200 mA
20 A
10 mA
Burden voltage:
500 mV maximum in the 20 A range
350 mV maximum in all other ranges
Maximum voltage: 250 volts maximum when measuring current
Alternating Current (50 Hz – 400 Hz)
Range
Resolution
1 µA
2 mA
10 µA
20 mA
100 µA
200 mA
20 A
10 mA
Burden voltage:
500 mV maximum in the 20 A range
350 mV maximum in all other ranges
Maximum voltage: 250 volts maximum when measuring current
Resistance
Range
Resolution
200 Ω
0.1 Ω
1 Ω
2 KΩ
10 Ω
20 KΩ
100 Ω
200 KΩ
1 K Ω
2 MΩ
10 K Ω
20 MΩ
Open circuit voltage: 3 VDC in the 200 Ω range
All manuals and user guides at all-guides.com
Accuracy
+/– (0.8% + 2 digits)
+/– (1.0% + 2 digits)
+/– (1.2% + 5 digits)
Accuracy
+/– (1.0% + 5 digits)
+/– (2.0% + 5 digits)
Accuracy
+/– (0.8% + 3 digits)
+/– (1.2% + 5 digits)
0.3 VDC in all other ranges
93-604 Multimeter
Overload Protection
200mA/250V fuse
20A/250V fuse
Overload Protection
200mA/250V fuse
20A/250V fuse
Overload Protection
500 VDC/VAC RMS
17