If the problem cannot be solved, take the battery to an Authorized Service Point.
5.2.1

ON/OFF battery led light

When the button is pressed while switching off the battery, the timed lit-up led bars quantity will decrease up to zero.
When the last LED bar is off, the battery switches off by releasing the button.
5.2.2

ON/OFF power supply management

When the battery is off, it is switched on by pressing the button. The charge level can be seen for 5 seconds.
When the battery is off, it is switched on by connecting it to the charger. The charge level can be seen on as long as
the charger is connected.
If the consumption is less than 200 mA, the self-switching-OFF timer is activated. Timing depends on the battery pack
status of charge (SoC).
The operator can switch off the battery by keeping the button pressed for at least 5 seconds.
The battery switches off automatically, when the charger is disconnected or when charge is complete
While the battery is charging, it cannot be switched off.
5.3

Battery re-charging

For the recharge operations please read the manual of the battery-charger.
5.4

Troubleshooting

All the following maintenance operations shall be carried out by a mechanical maintenance technician.
FAULT
The battery does not turn on
The battery is off
The battery display is flashing Error detected
6.1

Routine maintenance

Before any routine maintenance operation, put the button in OFF (4) position. All maintenance operations which
are not describe in this manual shall only be carried out by Authorized Service Points.
6.1.1

Storing the unit and maintaining its battery set

Before storing the unit for a prolonged period:
Charge the battery set (2) up.
Every 180 days repeat a complete battery (2) charge cycle.
Store the unit in a dry place inside its case. Do not leave it under the rain.
If a battery recharge cycle is not carried out every 180 days, the battery set (2) gets definitely damaged (see par.
6.1.1).
6.2

Special maintenance

Any different maintenance operation not shown on this manual shall be carried out by an Authorized Service
Point only.
Extraordinary maintenance operations must be performed by a mechanical maintenance technician or an electri-
cal / electronic one.
Use and maintenance manual – Translation of
original Instruction Rev.: 02, Data 08/11/2021
CAUSE
Flat battery
Auto switch-OFF entered
RIMEDY
Re-charge the battery
Turn the battery ON (4) by means of the switch.
Switch the battery off and on again to reset the error.
Pag. 21