Troubleshooting - STEINEL Spot Way Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 56

12. Troubleshooting

Malfunction
LED light does not switch
ON
NightAuto LED light
does not switch ON
NightAuto LED light does not
switch OFF
SC LED light keeps
switching ON/OFF
Cause
■ Fuse has tripped,
not switched ON,
break in wiring
■ Short circuit
■ Lamp faulty
■ Twilight setting in
night-time mode during
daytime operation
■ Mains switch OFF
■ Fuse has tripped
■ Detection zone not
correctly adjusted
■ The twilight setting is
set to permanently ON
during night-time
operation
■ Continued movement
within the
detection zone
■ Light-level sensor is
covered (e.g. by
leaves).
■ Animals moving in
detection zone
– 27 –
Remedy
■ Activate, change fuse,
turn ON mains switch,
check wiring with
voltage tester
■ Check connections
■ Change lamp
■ Reset
■ Switch ON
■ Activate, change fuse,
check connection if
necessary
■ Readjust
■ Reset
■ Check zone and
readjust if necessary or
apply shroud
■ Remove shrouds from
light-level sensor
■ Tilt sensor higher or fit
shrouds to target
sensor;
adjust detection zone
or fit shrouds

Publicidad

Tabla de contenido
loading

Tabla de contenido