All manuals and user guides at all-guides.com
•
Install a flexible coupling
between the air discharge outlet
and main air distribution line to
allow for vibration.
FEEDER LINES SLOPE
AIR FLOW
WITH AIR FLOW
MAIN DISTRIBUTION AIR LINES
Slope pipe in direction of air flow.
Water condensate flows along
bottom of pipe to drain legs,
preventing it from entering feeder
lines.
REGULATOR
LUBRICATOR
MOISTURE
SEPARATOR
AND TRAP
DIRT
LEG
TYPICAL COMPRESSED
AIR DISTRIBUTION SYSTEM
•
AIR USAGE
LINES
DIRT
LEG
DRAIN
TRAP
13- ENG
A separate regulator is
recommended to control the air
pressure. Air pressure from the
air tank is usually too high for
individual air driven tools.
AIR FLOW
DRAIN
TRAPS
REGULATOR
FILTER
FLEXIBLE
COUPLING
AIR DISCHARGE
VALVE
COMPRESSOR
DRAIN COCK
VALVE
DRAIN
LEGS
LUBRICATOR
AIR
D24917