PROBLEM
Knocking Noise. Possible defect in safety
valve.
Defective check valve.
Loose pulley
Loose flywheel
Compressor mounting
screws loose
Loose belt
Carbon build-up in pump
Belt to tight
Excessive belt
Loose belt.
wear
Tight belt.
Loose pulley.
Pulley misalignment.
D24917
CAUSE
Operate safety valve manually
by pulling on ring. If valve still
leaks, it should be replaced.
Remove and clean, or replace.
Tighten pulley set screw, see
Repair Parts section for torque
specifications.
Tighten flywheel screw, see
Repair Parts section for torque
specifications.
Tighten mounting screws,see
Repair Parts section for torque
specifications.
Loosen wingnut and then
tighten wingnut until it
contacts the washer, plus one
turn.
Have checked by a Sears or
other Trained Service
Technician.
Loosen wingnut and then
tighten wingnut until it
contacts the washer, plus one
turn.
Loosen wingnut and then
tighten wingnut until it
contacts the washer, plus one
turn.
Loosen wingnut and then
tighten wingnut until it
contacts the washer, plus one
turn.
Have checked by a Sears or
other Trained Service
Technician.
See Motor Pulley/Flywheel
Alignment paragraph in the
Maintenace section.
26- ENG