The KIT AC-MAX 2 DOORS (Fig. 1) allows:
-
2 doors with 2 Wiegand readers (1 Wiegand input reader, per door)
-
2 doors with 4 Wiegand readers (1 Wiegand input reader and 1 Wiegand output reader, per
door)
-
2 doors with 2 fingerprint readers (RS485) (1 fingerprint reader (RS485) input, per door)
-
2 doors with 4 fingerprint readers (RS485) (1 input fingerprint reader (RS485) and 1 reader
reader output footprint, per door)
The AC-MAX 4 DOORS KIT (Fig. 2) allows:
-
4 doors with 4 Wiegand readers (1 Wiegand input reader, per door)
-
4 doors with 4 fingerprint readers (RS485) (1 fingerprint reader (RS485) input, per door)
-
4 doors with 8 fingerprint readers (RS485) (1 input fingerprint reader (RS485) and 1 reader
reader output fingerprint per door)
INSTALLATION.
It is necessary to wire the power of the kits. See examples with Wiegand readers and RS485 fingerprint
readers.
* These readers feed directly from the kit power supply, if consume more than 100mA individually.
Fig.3 Power supply diagram of the expander and the AC-MAX control unit with Wiegand readers (kit
ref.5223).
Fig.4 Power supply diagram of the expander and the AC-MAX control unit with RS485 fingerprints readers
(kit ref.5223).