Table 4: Technical Specification
Supply voltage
Backup battery
Current consumption
Inputs
Relay outputs
Transistor outputs
Power supply outputs
RS485 ports
Ethernet port
Wire lengths
Environmental class
(acc. to EN 50131-1)
Dimensions H x W x D
Weight
Certifications
I
NSTALLATION
Fig. 9 Connecting Wiegand readers to AC-MAX board. Resistors already connected internally in the control
panel, it is not necessary to connect them externally.
All manuals and user guides at all-guides.com
11.5Vdc-15Vdc, nominal 12Vdc,
13.8Vdc/7Ah, charging current 300mA
100 mA for 18Vac (no loads on AUX/TML)
Eight inputs, electrically biased to +12Vdc via 5.6kΩ resistor
Two relay outputs with single NO/NC contact 30Vac-dc/1.5A rated
Six open collector transistor outputs, 15Vdc/150mA rated. Max. total current
sink by all outputs up to 3A dc.
12Vdc/0.2A (TML)
Two RS485 communication ports
10BASE-T 10/100Mb communication port
1200m for RS485
150m for Wiegand and AC-MAX CLK/DTA
Class I, indoor general conditions, temperature: +5°C to +40°C, relative
humidity: 10 to 95% (no condensation)
72 x 175 x 30 mm
approx. 200g
CE
D
IAGRAMS
34/46