5.1
SELEZIONI FUNZIONI / SELECTION OF FUNCTIONS / SELECCIÓN DE LAS FUNCIONES
G
P s
G
P s
L
N
FA FC F
FC
FA
0V 12V 24V
-BATT+
FC
F
10 11 E1 TS
L1T
L2T
M
N
FA
0 0 0 0 0 1
Ref.Des.
00000
1 2 3 4 5 6 7 8
LINE FUSE 3A
120V =3A
230V=3,15A
+BATT-
G
Ps
MOTOR FUSE 10A
0
12 24
0V 12V 24V
G
Ps
G
Ps
FROM BATTERY CHARGER
TO BATTERY CHARGER
R20
ACCESSORIES
CONTROL BOARD
FUSE 2A
FUSE 630mA
1 ON
Funzione chiusura automatica
attivata;
2 ON
Funzione "Apre-stop-chiude-
stop" con pulsante (2-7) e
radiocomando (scheda AF inserita)
attivato;
2 OFF Funzione "Apre-chiude" con
pulsante (2-7) e trasmettitore radio
(scheda AF inserita) attivato;
3 ON
Funzione "solo apertura" con
trasmettitore radio(scheda AF
inserita) attivato;
4 ON
"Prelampeggio in apertura
e chiusura" attivato; dopo un
comando di apertura o di chiusura,
il lampeggiatore collegato su 10-
E1, lampeggia per 5 secondi prima
di iniziare la manovra;
5 ON
Rilevazione
dell'ostacolo
attivato; a motore fermo (porta
chiusa, aperta o dopo un comando
di stop totale),impedisce qualsiasi
movimento se i dispositivi di
sicurezza (es. fotocellule) rilevano
un ostacolo;
6 ON
Funzionead"azionemantenuta"
attivato;funzionamento
cancello mantenendo premuto
costantementeilpulsante,pulsante
collegato su (2-3) per l'apertura e
(2-4) per la chiusura, esclude la
funzione del radiocomando;
7 OFF Funzione di riapertura in fase
di chiusura (collegare il dispositivo
di sicurezza sui morsetti 2-C1)
attivata; (se non vengono utilizzati
i dispositivi su 2-C1 posizionare il
dip 7 in ON);
8OFF
Funzione di richiusura in fase
di apertura (collegare il dispositivo
di sicurezza sui morsetti 2-C2)
attivata; (se non vengono utilizzati
dispositivi su 2-C2, posizionare il
dip 8 in ON);
9OFF
Funzione di stop parziale
(collegareildispositivodisicurezza
sui morsetti 2-C3) attivato; (se non
vengono utilizzati i dispositivi su
2-C3, posizionare il dip 9 in ON);
10 ON Funzione del test di sicurezza
per la verifica dell'efficenza delle
fotocellule attivato;
B1 B2
1
2
3
3P
4
5
7
2
C1
C2
C3
+AL
CONTROL BOARD
ZBK241
CAME
AF
CH1
CH2
PROGRAM.
ALIM.
PROG.
C1
C2
C3
STOP
+ SENS.-
+ T.A.C.-
+ T.P.A.-
ON
1
2
3 4 5 6 7 8 9 10
1 ON
Automatic closure function acti-
vated;
2 ON "Open-stop-close-stop"
with pushbutton (2-7) and remote
control (HF card inserted) activated;
2 OFF "Open-close" function with push-
button (2-7) and radio transmitter
(HF card inserted) activated;
3 ON "Opening only" function with radio
transmitter(HF card inserted) activa-
ted ;
4 ON "Pre-flashing opening and clo-
sing" activated; after an opening
or closing command, the flashing
lamp connected on 10-E1 flashes
for 5 seconds before the manoeuvre
begins
5 ON Obstacle detectionactivated; with
motor off (bar closed, open or after
a total-stop command), if the safety
devices (e.g. photoelectric cells)
detect an obstacle, all movements
are prevented;
6 ON "Maintained
activated; bar functioning, keeping
the pushbutton down, pushbutton
del
connected on (2.-3) for opening and
(2-4) for closing (excludes the remo-
te control function)
7 OFF Re-opening during closure func-
tion activated (connect safety device
on terminals 2-C1) ; (if devices on
2-C1 are not in use set dip-switch 7
to ON);
8OFF
Re-closing during opening fun-
ction activated (connect the safety
device on terminals 2-C2) ; (if the
devices on 2-C2 are not in use, set
dip switch 8 to ON)
9OFF
Partial stop function activated
(connect the safety device on termi-
nals 2-C3) ; (if the devices on 2-C3
are not in use, set dip switch 9 to
ON)
10 ON Safety test function for checking
the efficiency of the photoelectric
cells activated;
� �
ON
� � �
OFF

DIP-SWITCHES (1-10)

1 ON Función cierre automático activa;
2 ON Función"abrir-parada-cerrar-pa-
function
2 OFF Función"abrir- cerrar"con botón
3 ON Función "sólo abrir" con
4 ON "Predestello durante apertura
5 ON Detección de obstáculos activa;
action"
function"
6 ON Función de "accionamiento
7 OFF Función de reapertura durante
8 OFF Función de cierre durante la
9 OFF Función de parada parcial
10 ON Función del test de seguridad
� �
� �
� � � � � � � � � � � � � � �
rada"con botón (2-7) y radiomando
(tarjeta AF conectada) activa;
(2-7) y transmisor radio (tarjeta AF
conectada) activa;
transmisor radio (tarjeta AF
conectada) activa;
y cierre" activa; después de un
mando de apertura o de cierre,
la luz intermitente, conectada en
10-E1,destella durante 5 segundos
antes de comenzar la maniobra
con el motor detenido (puerta
cerrada, abierta o después de
un mando de parada total),
impide cualquier movimiento si
los dispositivos de seguridad
(por. ej. fotocélulas) detectan un
obstáculo;
continuo" activa; funcionamiento
de la cancela manteniendo
apretado constantemente el
botón, botón conectado en (2-3)
para la apertura y (2-4) para el
cierre, desconecta la función del
radiomando;
el cierre (conecte los dispositivos
de seguridad en los bornes 2-
C1) activa; (si no se utilizan los
dispositivos en 2-C1, coloque el
dip 7 en ON);
apertura (conecte los dispositivos
de seguridad en los bornes 2-
C2) activa; (si no se utilizan los
dispositivos en 2-C2, coloque el
dip 8 en ON);
(conecte los dispositivos de
seguridad en los bornes 2-C3)
activa; (si no se utilizan los
dispositivos en 2-C3, coloque el
dip 9 en ON);
para el control del funcionamiento
de las fotocélulas activa;
6
.6
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bk-1800Bk-2200Bke-1200Bke-1800Bke-2200Bk-241