Before using the riveter and to make it easier to
remove self-piercing rivets, it is possible to make an
impression on the rivet with the centre punch tool
(ref. 048379) so that the extraction die is subsequently
wedged in the impression.

CHECKS AND MAINTENANCE

The GYSPRESS 10T PP CONTROL riveter does not require any special maintenance. A simple periodic visual check is
recommended in order to prevent any breakdowns or possible failure during use.
Clean the GYSPRESS 10T PP CONTROL riveter at least once a week to remove any dust and dirt that may affect the
long-term performance of the product. Use self-cleaning cloths. Do not use water, flammable or corrosive liquids.
ANOMALIES, CAUSES, REMEDIES
The table below shows the possible issues that can be encountered when using the tool. If the problem encounte-
red is not listed in the table below, stop using the tool and contact your dealer immediately to find the procedure to
follow.
Issues
The riveter is not working
The rivet is not positioned correctly
Air, sealing fault causing leakage

CONDITIONS OF WARRANTY

The warranty covers any manufacturing defect or general defect for two years from the date of purchase (parts and
labour). The warranty excludes incidents due to misuse, dropping, dismantling or any other damage due to transport.
The warranty does not cover the normal wearing of parts. Only spare parts from GYS should be used to carry out a
repair on the GYSPRESS 10T PUSH PULL riveter.
38
WORKSTATION GYSPRESS 10T PP CONTROL
The compressed air is not connected
Mains power is not connected
Compressed air is not
correctly set up
Lack of oil
Defective mandrel or die
The die is not suitable
The pressure force is not suitable
Wrong rivet length
Defective hose
Defective coupling
Defective seal
If during extraction the rivet remains in the die's hole,
blow to release it before performing another extraction.
Stop moving the tip of the die forward as soon as the
rivet has been removed. Bringing the tip to a complete
stop can generate stress on the tip
CAUSES
and break it.
SOLUTIONS
Connect compressed air
Connect the mains supply
Adjust the compressed air to 7 bar
Check that the riveter
is sufficiently filled with oil
Replace mandrel or die
Replace mandrel or die
Adjust the pressure force
Follow the instructions
the manufacturer;
Replace air hose
Replace coupling
Have the part repaired by the manufacturer