Specifications; Before Returning For Repairs - Schumacher Electric XC12-CA Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PROBLEM
The charger will not turn on
when properly connected.
I cannot select a 6V or 12V
setting.

14. SPECIFICATIONS

XC12-CA
Input Voltage ..................................................................................120V AC @ 60Hz, 2.9A
Output Voltage .......................................................6V or 12V, with Auto Voltage Detection
Output Current Rating ..............................................2A DC @ 6V DC; 12A DC @ 12V DC
XCS15-CA
Input Voltage ..................................................................................120V AC @ 60Hz, 3.6A
Output Voltage .......................................................6V or 12V, with Auto Voltage Detection
Output Current Rating ..............................................2A DC @ 6V DC; 15A DC @ 12V DC
XCS15W
Input Voltage ..................................................................................120V AC @ 60Hz, 3.6A
Output Voltage .......................................................6V or 12V, with Auto Voltage Detection
Output Current Rating ..............................................2A DC @ 6V DC; 15A DC @ 12V DC

15. BEFORE RETURNING FOR REPAIRS

If these solutions do not eliminate the problem, or for more information
about troubleshooting, contact customer service for assistance:
For REPAIR OR RETURN, contact Customer Service at 1-800-621-5485. DO NOT SHIP
UNIT until you receive a RETURN MERCHANDISE AUTHORIZATION (RMA) number
from Customer Service at Schumacher Electric Corporation.
POSSIBLE CAUSE
AC outlet is dead.
Poor electrical connection.
Battery is defective.
The charger is equipped
with Auto Voltage Detection,
which automatically detects
the voltage and charges the
battery.
services@schumacherelectric.com
www.batterychargers.com
or call 1-800-621-5485
Monday-Friday 7:00
• 9 •
Check for open fuse or circuit
breaker supplying AC outlet.
Check power cord and
extension cord for loose
fitting plug.
Have battery checked.
No problem; this is normal.
to 5:00
CST
am
pm
REASON/SOLUTION

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Xcs15-caXcs15w

Tabla de contenido