BFT VISTA-SL ARIA-EVO Serie Instrucciones De Uso Y De Instalacion página 28

Automatizaciones para puertas
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
x 2
add. start
Add. 2ch
erase 64
language
autoset
Control unit
software version
stat
vers
OK
- +
No total
manoeuvres(in hundreds)
n. cycles
OK
- +
No radio control
devices memorised
n. remotes
OK
- +
List of last 30 errors
err
OK
0---
password
A
28
- VISTA-SL (ARIA-EVO)
ACCESS MENUS Fig. C1
See PARAMETERS MENU
See LOGIC MENU
hidden butt
release
desired button
hidden butt
release
desired button
DIAGNOSTICS
CODE
STOP input activated
stop
Open-key input activated
ey
INTERNAL RADAR input activated
intr
EXTERNAL RADAR input activated
extr
OPENING SAFETY DEVICE input activated
opph
CLOSING SAFETY DEVICE input activated
clph
OPENING SAFETY DEVICE WITH
OPDZ
"DETECTION ZONE" input activated
Multifunction input activation
ltf, d - n -
Error in safety device test during opening
Er03
Error in safety device test during closing
Er04
Encoder disconnected or faulty
Er21
Encoder wrong way round with respect to motor
Er22
rotation
Communication error with operation board for
ER50
operation with "ELA SL 24.B KIT "
Error in communication between automatic doors in
bft . . .
Er52
cage mode.
+/-
Error in communication with devices connected to
Er53
RS485 serial line.
0000
+/-
*
Board hardware test error
ER1x
*
Reverse due to obstacle - Amperostop
ER3x
00
*
Thermal cutout
+/-
ER4x
*
Internal system supervision control error.
ER7x
01.33
solenoid lock output overload
02.01
erf9
autoset function is running. WARNING! Obstacle
........
SET
detection function is not active
*X= 0, 1, .., 9, A, B, C, D, E, F
30.15
+/-
150-
10--
Opening
G
B
C
E
https://appceso.com
See RADIO MENU
DESCRIPTION
1520
Fig. C2
F
Scroll up
Scroll down
Con rm/Switch on display
Exit Menù
NOTES
 
 
 
 
- Check connections to motor
- Hardware problems with board (contact technical
assistance)
Check for obstacles in path
Allow automated device to cool
Try switching the board off and back on again. If the
problem persists, contact the technical assistance
department.
check solenoid lock connections
prg
Closing
H
B
A
D

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido