Before starting the unit you must read, take into consideration
and comply with all the indications described in this Manual.
This manual must be kept in a safe place, accessible to all
users of the unit.
The unit must be started and handled exclusively by
personnel instructed in its use and must be employed only
for the purpose for which it was designed.
This unit belongs to the family of devices designed to spray
products with compressed air by means of a spray gun. They
provide a high level of product transfer (T > 65%) and
excellent quality finish, as well as low levels of contamination.
The equipment consists of the following standard features:
- Pump model MACK 400 - MACK 600
- Instruction manual
- Case
Unit featuring a pneumatic cylinder that activates the hydraulic
device which provides the pressure necessary to spray the
product.
Pneumatic cylinder
Unit supply
Engine stroke
Maximum air consumption (60 cycles/Minute)
Maximum pressure at air inlet
Minimum Ø of supply hose
Lubricator Oil
Packing Gland Oil
Maximum Pressure at the product outlet
Free flow-rate (60 cycles/minute)
Flow-rate per cycle
Air inlet
Product Inlet
Product Outlet
MAXIMUM Spray air cap size
Air cap size for two guns
Dimensions:
Net Weight:
Work pressure engraved on the Airless Gun
CE Approvals

1. WARNING

2. INTRODUCTION

3. TECHNICAL DETAILS

Ex II 2G X
- 16 -
Likewise, accident prevention standards, work centre
regulations and directives and current legislation and
restrictions must be taken into consideration at all times.
SAGOLA S.A., the SAGOLA logotypes and other SAGOLA
products mentioned in this manual are registered trademarks
or brand names of the company SAGOLA S.A.
As optional and complementary elements of the equipment,
in this Manual the following are included:
-Product hoses
-Airless and Mixed Gun
-Spray air caps
- Fixed Spray Fan
- Rotational (Self-cleaning)
- Mixed
The unit can be supplied in a suction probe version, which
is inserted directly in the container of the product to be
applied.
Mack 400
Ø 180 mm.
Treated Compressed Air
95 mm.
1,700 Litres/minute
6 bar
12.7 mm.
SAE 10
SAGOLA 30090098 Lubricant
240 bar (3,481 psi)
7.2 litres/minute
120 cc.
Quick coupling BSP 1/2"
Tube Ø13xØ16
BSP 3/8" M
545x546x1,007 mm.
62 kg.
Mack600
360 bar (5,221 psi)
5.2 Litre/minute
86 cc.
0.032"
0.018"
63 kg.