1
Absorption probe
2
Product return hose
3
Product return key
4
Pressure Regulator
5
Product Outlet
6
Pressure gauge (Unit)
7
Air inlet
8
Product inlet
9
Packing nut
10
Anti-pulsation filter
1
- Before putting the unit into operation, and especially after
each cleaning and/or repair operation, a check must be made
that the equipment components are securely tightened and
that the hoses are airtight (no leaks). Faulty parts must be
replaced or repaired as appropriate.
- The Unit is easy to handle thanks to its design and the simplicity
of its mechanisms. No special training is required for handling the
unit. Use it according to the operating, maintenance and safety
instructions indicated in this manual and follow the application
methods indicated to obtain the required quality of finish.
- Before putting the unit into operation, we recommend that you
clean the equipment as this has been subjected to functional
tests and before packaging it is treated internally with a protective
coating, some of which may still remain. Apply thinner to eliminate
this. Remove any residual grease applied during assembly.
- The unit is depressurised when supplied (no pressure inside).
- Ensure that the products to be applied are chemically
compatible with the components these come into contact with
(aluminium, stainless steel, polythene and acetylene resin).
- Do not use corrosive or abrasive products.
- Use SAGOLA anti-static hoses suited to the product to
be transferred.
- You must always connect the equipment and all the
elements involved in the work process to a grounding
4. COMPONENTS
10
7
5
3
2
8
5. WARNINGS
connection to eliminate static electricity. Regularly verify (one
a week) its electrical continuity. If its resistance exceeds the
recommended limits, it must be fixed. An equipment unit
without or with a faulty grounding connection may make the
installation dangerous.
- The total derivative resistance must be <1M ohms (Ω).
The unit has been designed for long service and can be
used with most products available on the market. Its use
with highly aggressive products will quickly increase the
need for maintenance and spare parts. If you need to apply
special products, please contact SAGOLA S.A.
- Read and apply all the information, instructions and safety
measures indicated by the manufacturer of the products to
be applied (products to be applied, thinners, etc.) as these
may provoke chemical reactions, fires and/or explosions, or
be toxic, irritant or harmful and in all cases dangerous for
the health and personal safety of the user and of other
persons nearby (see chapter on Safety and Health).
- Mix, prepare and filter the product to be applied in accordance
with the manufacturer's instructions, ensuring that any foreign
bodies are prevented from spoiling the quality of finish and
application. Should there be any doubt related to the purity of
the product, its composition, etc. please contact your supplier.
Control the viscosity of the product to be applied with the
SAGOLA Viscosimeter kit- Code 56418001
- 17 -
4
6
9