Thermador PRO GRAND PROFESSIONAL Serie Manual De Instalación página 11

Ocultar thumbs Ver también para PRO GRAND PROFESSIONAL Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Gas and Electric Supply Zones
36" (913 mm)
48" (1219 mm) 23⅛" (587 mm) 7" (178 mm)
NOTICE:
— If not already present, install gas shut-off valve in an
easily accessible location.
— Make sure all users know where and how to shut off
the gas supply to the range.
— Any opening in the wall behind the appliance and any
opening in the floor under the appliance must be
sealed.
The range must be connected only to the type of gas
for which it is certified. If the range is to be connected to
propane gas, ensure that the propane gas supply tank is
equipped with its own high pressure regulator in addition to
the pressure regulator supplied with the range (see "Step 6:
Gas Requirements and Hookup" on page 14).
NOTE:
The range is designed for flush installation to the back wall.
For a successful installation, it may be necessary to
reposition the gas-supply line and electrical cord as the
range is pushed back to its final position.
SUGGESTION: Carefully pull on a rope or twine looped
around the gas or electrical supply line as the range is
pushed back into its final installed position.
English 8
36" or 48" (914 or 1219 mm)
GAS ZONE
10"
(254 mm)
A
Model
A
9⅛" (232 mm)
Range Width
ELECTRICAL
ZONE
3"
(76 mm)
B
C
B
7⅜" (187 mm) 7⅜" (187 mm) 9⅛" (232 mm)
7" (178 mm)
IMPORTANT:
The cord supplied with the gas ranges, having an electric
griddle, requires a NEMA 5-20 receptacle, shown here.
Local codes may require a different wiring method.
WARNING!
This appliance is equipped with a three-prong grounding
plug for protection against shock hazard and should be
plugged directly into a properly grounded receptacle. DO
NOT cut or remove the grounding prong from this plug.
DO NOT ALTER THIS PLUG.
2" (51 mm) max.
2" (51 mm) max.
2" (51 mm) max.
protrusion from wall
protrusion from wall
protrusion from wall
for gas or electrical
for gas or electrical
for gas or electrical
supply.
supply.
supply.
D
C
D
7⅞" (200 mm)
Figure 4: Gas & Electrical Supply Locations

Publicidad

Tabla de contenido
loading