Vario III
Key:
Protection Telnet
Key:
Protection remote access
NOTICE!
In order to execute a blocked function, first of all the valid password has to be entered. If the correct password is
entered then the desired function can be executed.
Interface
Keys:
,
,
,
COM1 / Baud / P / D / s
Key:
Start sign / End sign
Key:
Data memory
Key:
Port test
Emulation
Keys:
,
,
,
Protocol
104
The settings of the Telnet service cannot be changed.
The password protection prevents the remote control of the printer.
,
,
,
COM1:
0 - serial interface Off
1 - serial interface On
2 - serial Interface On; no error message occurs in case of a transmission error.
Baud rate:
Indication of bits which are transferred per second.
Following values are possible: 1200, 2400, 4800, 9600, 19200, 38400, 57600 and 115200.
P = Parity:
N - No parity
E - Even
O - Odd
Please observe that the settings correspond to those of the printer.
D = Data bits
Setting of data bits.
Value range: 7 or 8 Bits.
S = Stop bits
Indication of stop bits between bytes.
Value range: 1 or 2 stop bits.
SOH: Start of data transfer block
ETB: End of data transfer block
Standard: After starting a print order the printer buffer receives data as long as it is filled.
Advanced: During a current print order data is received and processed.
Off: After starting a print order no more data is received.
Check whether the data are transferred via the interface.
Press the
and
keys to select standard (on). Press the
any port (COM1, LPT, USB, TCP/IP) is printed.
,
,
,
,
CVPL: Carl Valentin Programming Language
®
ZPL: Zebra
Programming Language
Press keys
and
to select the protocol. Press key
printer is restarted and ZPL II
English
Hex format 01
Hex formal 17
®
commands are transformed internally into CVPL commands.
key and the data sent via
to confirm the selection. The