Technical specifications
Size
Single-acting drives
Switching time per cycle
DAPS-0008-...
–
DAPS-0015-...
0.2
DAPS-0030-...
0.5
DAPS-0053-...
0.9
DAPS-0060-...
–
DAPS-0090-...
1.3
DAPS-0106-...
–
DAPS-0120-...
1.7
DAPS-0180-...
2.7
DAPS-0240-...
3.7
DAPS-0360-...
3.9
DAPS-0480-...
3.1
DAPS-0720-...
5.8
DAPS-0960-...
6.3
DAPS-1440-...
19.0
DAPS-1920-...
15.0
DAPS-2880-...
19.0
DAPS-3840-...
–
DAPS-4000-...
25.0
DAPS-5760-...
–
DAPS-8000-...
–
1) The switching times are specified in seconds and represent average values under idling conditions
Operating conditions DAPS
double-acting
1)
Work pressure
[bar]
Rated operating pressure
[bar]
Operating medium
Note on the operating medium
Ambient temperature
[°C]
ATEX ambient temperature
[°C]
Swivel angle
[°]
End-position adjusting
[°]
range at 0°
End-position adjusting
[°]
range at 90°
Mounting position
Tubing
Materials
Drive shaft
Cover
Housing
Exceptions for devices with special marking
1)
Operating conditions DAPS
single-acting
1)
Work pressure
[bar]
Rated operating pressure
[bar]
Operating medium
Note on the operating medium
Ambient temperature
[°C]
ATEX ambient temperature
[°C]
Swivel angle
[°]
End-position adjusting
[°]
range at 0°
End-position adjusting
[°]
range at 90°
Mounting position
Tubing
Materials
Drive shaft
Cover
Housing
1) Minimum operating pressures vary for single-acting quarter turn actuators depending upon spring
quantity
Double-acting drives
1)
[s]
Switching time per cycle
0.08
0.08
0.13
–
0.2
–
0.4
–
0.6
0.8
1.2
1.6
2.7
3.1
5.5
6.0
16.0
12.0
–
16.0
22.0
DAPS-
DAPS-
DAPS-
DAPS-
0008
0015 ...
0480 ...
2880 ...
0360
1920
5760
2.8 ... 8.4
5.6
Compressed air to ISO 8573-1:2010 [7:4:4]
Lubricated operation possible (required for continued
operation)
–20°C ... +80
–20°C ≤ Ta ≤ +60
90
–
–
–
±5
–
±2
±2
±5
as desired
dia. = 8 mm
high-alloy steel
wrought aluminium alloy
wrought aluminium alloy
DAPS-
DAPS-
DAPS-
0015 ...
0240 ...
1440 ...
0180
0960
1920
2.8 ... 8.4
5.6
Compressed air to ISO 8573-1:2010 [7:4:4]
Lubricated operation possible (required for continued
operation)
–20°C ... +80
–20°C ≤ Ta ≤ +60
90
–
–
–
±2
±2
±2
as desired
dia. = 8 mm
high-alloy steel
wrought aluminium alloy
wrought aluminium alloy
1)
[s]
DAPS-
8000
1 ... 7
DAPS-
2880,
4000
±5
±5