Repairs; Accessories; Eliminating Faults - Festo DGCI Instrucciones De Utilizacion

Ocultar thumbs Ver también para DGCI:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
DGCI-...
9

Repairs

S
Recommendation: Send the product to our repair service. The necessary accu-
rate adjustments and tests will then be taken into consideration.
S
Information on spare parts and assistant devices can be found under
www.festo.com/spareparts
Replacing cushioning elements
S
Note the section "Accurate adjustment of the stroke" in the chapter
"Commissioning".
10

Accessories

Note
S Please select the appropriate accessories from our catalogue
www.festo.com/catalogue
11

Eliminating faults

LED display on measuring system
Status LED
(Power: green)
Off
Off
On
On
Flashes
Fig. 28
Festo DGCI-...-Z6 1207b English
Fault LED
(Error: red)
Off
On
Off
On
Flashes
Meaning
No voltage
Initialization fault
Normal function
Magnet not recognized or incorrect number of magnets
Operating voltage not within permissible range
41

Publicidad

Tabla de contenido
loading

Tabla de contenido