Magnetostrictive Linear Position Sensor – Profile Style
5
Startup (continued)
5.2.3

Setting the bus termination

To ensure a reliable bus level, the bus must be terminated
at both ends with a terminating resistor. If the BTL is
located at the end of the bus, the termination can be made
using DIL switch S1.10. Termination for S1.10 = ON.
5.2.4

Operating status LED

The CANopen
ErrorLED (red) shows the status of the
®
CANopen
physical layer and errors with respect to
®
missing CAN messages (SYNC, GUARD or HEARTBEAT).
No.
ERROR
Status
LED
1
Off
No error
2
Single
Warning limit
flash
reached
3
Flicker
AutoBaud/LSS
4
Double
Error event
flash
5
On
Bus off
Tab. 5-2:
LED display for Profibus encoder profile
If multiple faults are present at the same time the fault with
the highest number is displayed (e.g. if a warning limit was
reached and there is a Guard event at the same time, the
Guard event is displayed).
www.balluff.com
Description
Device working
without any errors.
At least one of the
error counters in the
CAN controller has
reached or
exceeded the
warning level (too
many error frames).
Automatic baud rate
recognition running
or LSS service
running (alternate
flickering with the
RUN LED).
A guard event or
heartbeat event has
occurred.
The CAN controller
status is BUS OFF.
The CANopen
 RUN LED (green) displays the status of the
®
CANopen finite state machine.
No.
RUN
Status
LED
1
Flicker
2
Single
STOPPED
flash
3
Flashing
PREOPERA-
TIONAL
4
On
OPERATIO-
NAL
Description of the individual modes:
Status LED
On
Illuminated
Off
Off
Flicker
Frequency approx. 10 Hz (50 ms off
and 50 ms on)
Flashing
Frequency approx. 2.5 Hz (200 ms off
and 200 ms on)
Single flash
Approx. 200 ms on, followed by
approx. 1000 ms off
Double flash
2 brief flashes of approx.  200 ms
separated by approx. 200 ms off,
followed by a long off phase of approx.
1000 ms
Detailed configuration instructions
can be requested on the Internet at
www.balluff.com or via email at
service@balluff.de.
Description
Automatic baud rate
recognition running or
LSS service running
(alternate flickering
with the ERROR LED)
The device has been
STOPPED.
The device is
PREOPERATIONAL.
The device is
OPERATIONAL.
Explanation