Battery Cable Connection - Firman H08051 Manual Del Usuario

Ocultar thumbs Ver también para H08051:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Battery Cable Connection

You will need to use 8mm box wrenches to connect the battery cables to battery.
NOTE:
The generator comes equiped with the positive red cable(red cable) already attached.
1. Verify the positive (+) battery cable (red boot) is securely tightened to the positive (+) battery
post. Make sure boot is over battery post.
2. Remove bolt M5X12 and M5 nut from black cable ring.
3. Remove vinyl cap from the negative(-) battery post. Locate negative (-) black cable and route
to the negative(-) battery post. Tight the cable with bolt M5X12 and M5 nut. Cover the post with
black boot.
Black Cable(-)
English
Black Cable
-
Black Boot
M5
Ring
Red Cable(+)
+
Page 09
M5X12
Customer Service: 1-844-FIRMAN1

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido