BM 2610027815 03-13_BM 2610027815 03-13.qxp 4/2/13 8:47 AM Page 7
Mo UNTING THE Ro LLER/MATERIAL
SUppo RT AND REpETITIvE STo p
1. Loosen the lock knobs and pull out both
table extensions approximately 4-inches
(102 mm) and lock into place.
2. With the Repetitive Stop facing outward,
slide the Roller/Material Support onto the
mounting plate with the bolt fitting into the
vertical slot. Make sure the material support
fully seats onto the mounting plate. See
Figure D.
3. Using the supplied Multi-purpose Wrench,
tighten the hex bolt until the Roller/Material
Support is secured.
4. Test for a secure fit by unlocking the table
extension and moving it in and out by the
Material Support. The Material Support
should remain secured.
FIG. D
1
Mo UNTING THE Ro LLERS To THE
MATERIAL SUppo RT
1. Unscrew the Phillips screw of the roller stand
with the Multi-purpose tool provided and
disassemble. If required, hold the lock nut on
the other side of the roller using a wrench (10
mm).
2. See Figure C for the two different configurations,
depending on the size miter saw you are
using, for aligning the individual rollers to the
material support with the internally threaded
rod.
Configuration 1 offers even support on both
sides for larger miter saws, while configuration 2
offers more support on either the front or back
for smaller sized miter saws.
3. Arrange the individual rollers as required and
slide the threaded rod through the rollers and
material support.
4. Once threaded through, secure the alignment
by replacing and tightening the Phillips Head
Screw.
2
-7-
FIG. C