Ocultar thumbs Ver también para SmartOnline S3MX:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 71
4. Control Panel and LCD Operations
Table 4.4: Measurement Items
Submenu
Item
L-N Voltage (V)
Input
Frequency (Hz)
L-N Voltage (V)
L-N Current (A)
Output
Frequency (Hz)
Power Factor
L-N Voltage (V)
Bypass
Frequency (Hz)
Power Factor
Sout (kVA)
Load
Pout (kW)
Load Level (%)
Positive Voltage (V)
Negative Voltage (V)
Positive Current (A)
Negative Current (A)
Remain Time (Sec)
Capacity (%)
Battery
Test Result
Charging Status
Temperature 01(°C)
Temperature 02(°C)
Temperature 03(°C)
Temperature 04(°C)
Temperature 05(°C)
* Output current at zero load or low load may indicate up to 1% current flow on the display due to inverter activity. For load power readings, go to the LOAD
submenu on the display.

4.2.5. Setup Screen

Touch the
to enter into the Setup submenu. It requires a password to access the General, SYSTEM, BATTERY and PRE-ALARM
submenus (as shown in Figures 4.10 and 4.11). The default password is 0000.
Explanation
Input phase voltage (L1, L2, L3). Units: 0.1V.
Input frequency (L1, L2, L3). Units: 0.1 Hz.
Output phase voltage (L1, L2, L3). Units: 0.1V.
Output phase current (L1, L2, L3). Units: 0.1A.*
Output frequency (L1, L2, L3). Units: 0.1 Hz.
Output power factor (L1, L2, L3).
Bypass phase voltage (L1, L2, L3). Units: 0.1V.
Bypass frequency (L1, L2, L3). Units: 0.1 Hz.
Bypass power factor (L1, L2, L3).
Apparent power. Units: 0.1kVA.
Active power. Units: 0.1kW.
The percentage of connected load. Units: 1%.
Battery positive voltage. Units: 0.1V.
Battery negative voltage. Units: 0.1V.
Battery positive current. Units: 0.1A.
Battery negative current. Units: 0.1A.
Battery remaining runtime. Units: 1 sec.
The percentage of the battery capacity. Units: 1%.
Battery test result.
Battery charging status.
Temperature of external battery pack. Units: 0.1°C.
Temperature of external battery pack through extra communication card T1. Units: 0.1°C.
Temperature of external battery pack through extra communication card T2. Units: 0.1°C.
Temperature of external battery pack through extra communication card T3. Units: 0.1°C.
Temperature of external battery pack through extra communication card T4. Units: 0.1°C.
SETUP
Enter Password
Figure 4.10 Setup Menu
26
GENERAL
SYSTEM
BATTERY
PRE-ALARM
PARALLEL

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido