Gas Requirements; Special Gas Requirements (Gas Models Sold In Massachusetts) - Samsung NX58M9960P Serie Manual De Instalación

Estufa gas pro de 30"
Ocultar thumbs Ver también para NX58M9960P Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation requirements
C2
C1
C4
C3
Fig. 1

Gas requirements

Provide adequate gas supply
This range is designed to operate at a pressure of 5 in (13 cm) of water column on
natural gas or 10 in (25 cm) of water column on LP gas (propane or butane).
Make sure you are supplying your range with the type of gas for which it is
designed.
Do not attempt to convert the appliance from the gas specified in this manual to a
different gas without consulting the gas supplier.
This range is convertible for use on natural or propane gas. If you decide to use
this range on LP gas, conversion must be made by a qualified LP installer before
attempting to operate the range.
For proper operation, the pressure of natural gas supplied to the regulator must be
between 5 in and 13 in (13 cm and 33 cm) of water column.
For LP gas, the pressure supplied must be between 10 in and 13 in (25 cm and
33 cm) of water column.
When checking for proper operation of the regulator, the inlet pressure must be at
least 1 in (2.5 cm) greater than the operating (manifold) pressure as given.
16 English
Install_NX58M9960PS_DG68-01009A-01_EN+MES+CFR.indb 16
1.
The counter top around the cut-out
should be flat and leveled (see hatched
area on Fig. 1).
2.
Before installing the unit, measure the
heights of the two cabinet sides (C1–
C4), front and back (See Fig. 1) from the
floor to the top of the counter.
3.
Level the range using the four leveling
legs so that the height from the floor
to the underside of the cooktop frame
is greater than the tallest cabinet
measurement by at least 1/16".
4.
Slide the unit into the cabinet (DO NOT
PUSH THE UNIT HARD). Make sure the
center of the unit aligns with the center
of the cabinet cut-out.
The pressure regulator located at the inlet of the range manifold must remain in
the supply line regardless of whether natural or LP gas is being used.
A flexible-metal appliance connector used to connect the range to the gas supply
line should have an I.D. of 0.5 in (1.3 cm) and be 5 ft (152 cm) in length for ease of
installation. In Canada, flexible connectors must be single-wall metal connectors no
longer than 6 ft (183 cm) in length.
Do not kink or damage the flexible metal tubing when moving the range.

Special gas requirements (gas models sold in Massachusetts)

COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS:
WARNING
Gas leaks may occur in your system, creating a dangerous situation.
-
Gas leaks may not be detected by smell alone.
-
Gas suppliers recommend you purchase and install a UL-approved
gas detector. Gas detector should be installed in accordance with the
manufacturers instructions.
Range must be installed by a qualified plumber or gas fitter by the State of
Massachusetts.
A T-handle manual gas valve MUST be installed in the gas supply line to your
range.
If a flexible gas connector is used to install your range, multiple flexible gas
lines must not be connected in series.
2017-12-14
2:39:58

Publicidad

Tabla de contenido
loading