5. Commissioning, operation / 6. Faults
The set pointers for the inductive contacts are freely adjustable over the
full scale range. For reasons of switching accuracy, switching reliability
and service life of the mechanical measuring systems, the switch points
EN
should be between 10 % and 90 % of the measuring span.

6. Faults

Personnel: Skilled personnel or service personnel
Tools: Suitable spanner
DANGER!
Danger to life from explosion
Through working in flammable atmospheres, there is a risk of
explosion which can cause death.
CAUTION!
Physical injuries and damage to property and the
environment
If faults cannot be eliminated by means of the listed
measures, the instrument must be taken out of operation
immediately.
22
Only rectify faults in non-flammable atmospheres!
Ensure that pressure or signal is no longer present and
protect against accidental commissioning.
Contact the manufacturer.
If a return is needed, please follow the instructions given in
chapter 8.2 "Return".
WIKA operating instructions models TGS55, TGS73 with 831 (Ex)