" by which you can adjust the fixture to the required / desired position (0-255) before the function calibration.
Then when the positioning is finished use the last "FCAL" function (Fixture calibration).
1. Calibration via the control board
Press [Enter] and the [Up] and [Down] keys in order to display the following messages: "Col1, Col2, PriS,
SGob, rGob, Grot " for very smooth function calibration. Select one of them, press [Enter] and use the [Up]
and [Down] keys in order to adjust their right value from 0 to 255. Then press [Enter] to confirm or [Mode]
to cancel and return to the menu. This can be repeated for each calibration parameter if it is required. When
the calibration is finished, it is necessary to use the "ArES" function in order to write the calibration values to
the memory (EEPROM) and to make a reset in order to check the newly adjusted positions of the colour,
gobo and effect wheels. When the reset of the fixture is finished, the display will show the "FCAL" message.
Press [Enter] to repeat the calibration or [Mode] to return to the "AdJ" menu.
2. Calibration via the external controller
Press [Enter] and the [Up] and [Down] keys in order to display the following messages: "Colo, EFEC,
rGob, Grot" - calibration parameters. Select one of them and press [Enter].
Now you can calibrate the colour, gobo and effect wheel by your controller. The DMX calibration protocol is
described in the table mentioned below.
DMX Calibration protocol:
DMX
1
Channel
COL.1
CALIBRATION
Function
0 - 255
DMX
9
Channel
PRISM
Function
STANDARD
PROTOCOL
After having calibrated required functions press [Enter] to confirm (or [Mode] to cancel and return to the
menu without reset by the "ArES" function) and use the "ArES" function in order to write the calibration
values to the memory (EEPROM) and to make a reset in order to check the new adjusted positions of the
colour, effect and rot. gobo wheels and gobo indexing.
2
3
COL.2
SGOB
CALIBRATION
CALIBRATION
0 - 255
0 - 255
SMOOTH MICROSTEP MOVEMENT
10
11
STATIC
ROTATING
GOBOS
GOBOS
STANDARD
STANDARD
PROTOCOL
PROTOCOL
4
5
RGOB
GROT
CALIBRATION
CALIBRATION
0 - 255
0 - 255
12
13
GOBO
IRIS
ROTATION
STANDARD
STANDARD
PROTOCOL
PROTOCOL
46/97
6
7
-
COLOURS 1
STANDARD
-
PROTOCOL
14
15
FOCUS
STROBE
STANDARD
STANDARD
PROTOCOL
PROTOCOL
51839570_V_1_0.DOC
8
COLOURS 2
STANDARD
PROTOCOL
16
DIMMER
STANDARD
PROTOCOL