Discharge Pipe and Pressure Tank Connections

To Household
Water System
Pressure Gauge
6 0
4 0
8 0
2 0
1 0
0
Pressure
Switch
Pre-Charged
Tank
Figure 6: Pre-charged Tank
Connections
To Household
Air Volume
Water System
Control
Standard
Tank
Air Volume
Priming Tee
Control Tube
and Plug
Relief Valve
6 0
4 0
8 0
2 0
1 0
0
Pressure
Drive Pipe
Switch
To Well
Figure 7: Standard Tank Connections
PRE-CHARGE TANk CONNECTION (Figure 6)
If your system uses a pre-charged tank, it should be connected to the pump
as shown in Figure 6. The relief valve must be capable of passing the entire
Relief Valve
pump capacity at 100 PSI pressure.
Check the pre-charge of air in the tank with an ordinary tire gauge. the pre-
charge is measured when there is no water pressure in the tank. Disconnect
power to the pump and drain the tank before checking the pre-charge. Your
pump has a 30/50 PSI switch, so the tank pre-charge pressure should be 28
PSI (that is, it should be 2 PSI lower than the cut-in pressure of the pressure
From
switch.
Well
No AVC is required for a pre-charged tank; the 1/8" NPT AVC port on the
pump body should be plugged.
STANDARD TANk CONNECTION (Figure 7)
If your system uses a standard tank, connect it to the pump as shown in
Figure 7. The relief valve used with a standard tank must be capable of pass-
ing the entire pump capacity at 75 PSI pressure.
Connect the Air Volume Control (AVC) tube to the 1/8" NPT AVC port
on the pump body. Run the tubing from the pump's AVC port to the AVC
mounted on the tank. See the instructions provided with tank and AVC for
details.
2110 0497
Use only PTFE pipe thread sealant tape for making all threaded
connections to the pump itself. Do not use pipe joint compounds on
plastic pumps: they can react with the plastic in pump components.
Make sure that all pipe joints in the suction pipe are air tight as well as
water tight. If the suction pipe can suck air, the pump will not be able to
pull water from the well.
Table I: Wiring Chart – Recommended Wire and Fuse Sizes
Model
115Volts:
HNAS-50
HNAS-75
HNAS-100
Suction Pipe
230 Volts:
From Well
HNAS-50
HNAS-75
HNAS-100
2096 0497
Sealing Pipe Joints
Branch
Max
Fuse
Load
Rating
0-100
HP
Amps
Amps
(0-30)
1/2
12.2
20
12(3)
3/4
14.8
20
12(3)
1
19.2
25
10(5.5)
1/2
6.1
15
14(2)
3/4
7.4
15
14(2)
1
9.6
15
14(2)
Distance in Feet (Meters);
Wire Size AWG (mm
)
2
101-200 201-300 301-400 401-500
(31-61)
(62-91)
(92-122) (123-152)
10(5.5)
8(8.4)
6(14)
8(8.4)
6(14)
6(14)
8(8.4)
6(14)
4(21)
14(2)
14(2)
12(3)
14(2)
14(2)
12(3)
14(2)
12(3)
10(5.5)
5
6(14)
4(21)
4(21)
12(3)
10(5.5)
10(5.5)