Be sure carbon
brush is in brush tube
with brush shunt moving
freely in side groove of tube.
Place brush spring over post with short leg
positioned downward as shown. Be sure spring
is completely down with short leg trapped against
'Y' shaped wall on brush card.
While holding spring in place, bring the long leg of
spring over the brush tube and through rear opening
of tube. Position rounded hook of spring in groove on
back of carbon brush. Be sure to check for free move-
ment between carbon brush, brush shunt and brush spring.
INSTALLING BRUSH SPRINGS ON
A BRUSH CARD ASSEMBLY WITH
FOUR (4) BRUSHES
There are two Right Hand Brush Springs
and two Left Hand Brush Springs. Follow
the instructions below for proper installation.
Black
Red
Brush Card Assy.
L
R
Wrong
Brush Shunt (4 places)
Right Brush Spring (2x)
Carbon Brush (4x)
Left Brush Spring (2x)
Correct
Short leg of spring
to the bottom