Starting / Stopping The Engine; Operation Hints; Misting Hints - Solo 451 Manual De Instrucciones

Atomizador
Ocultar thumbs Ver también para 451:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53
Starting / Stopping the engine ; Operation hints

11. Starting / Stopping the engine

Before every use and before every start of the
mistblower check and ensure the machine is in
good and safe condition. (throttle operation,
ignition switch, safety devices, shoulder strap
and check for fuel leaks)
During the starting procedure and while
operating the mistblower, the operator must
have secure footing and have a safe body
position.
The engine starting site should be at least 3
meters away from the refueling site.
Starting with cold engine
 Switch ignition switch to "I" position and close
liquid tap.
Fig. 7
Close choke with choke lever (10).
 Press primer (11) several times until fuel is
visible in the primer.
 Place your left hand on the formula tank of the
mistblower. Hold the starter handle (Fig. 1.Pos.
7) with your right hand and pull the handle up
slowly until resistance is felt. Then pull up firmly
and rapidly until the engine 'fires'.
 Once the engine tries to start, immediately open
the choke
and continue to start until the
engine is running.
Starting with warm engine after short stop
 Leave choke in "open" position
engine.
Shutting off engine
 Release throttle lever and move ignition switch
to "Stop" position until engine stops.
ENGLISH 12

12.1 Misting Hints

Open liquid tap: Lever in horizontal position  ON
Shut liquid tap: Lever in vertical position  OFF
(fig. 5)
The liquid output volume is adjusted by turning the
dosage sleeve to different positions.
When spraying predominantly upwards (tall trees)
we recommend using the liquid pump offered as an
accessory (part no.: 44 00 235)
Misting Output Guide
Dosage
sleeve
Position 1
Position 2
Position 3
Position 4
With wide-range nozzle (7), wide-angle grille (7a);
A and B: see Fig. 8
Note: The liquid pump attachment comprises a
special metering body, which should be installed
when using a liquid pump.
Please note: When using a liquid pump,
ensure that the tank contains sufficient
liquid. The liquid pump can sustain severe
damage, if it is permitted to run dry. When
using the equipment as a mister and as blower,
remove the pump for that reason.
Fig. 8
and start

12. Operation hints

A
B
l/min
l/min
l/min
0.60
0.15
0.55
1.15
0.25
1.20
2.25
0.40
2.30
3.00
0.45
3.05
A
B
l/min
0.50
1.20
2.10
3.00

Publicidad

Tabla de contenido
loading

Tabla de contenido