COMPONENTS
CONTROL PANEL COMPONENTS
1
1. 120 Volt AC, 20 Amp Duplex NEMA 5-20R
Receptacle: Receptacle can supply a maximum of
20 Amps.
2. 20 Amp AC Circuit Breaker: Circuit breaker limits
the current that can be delivered through the NEMA
5-20R receptacle to 20 Amps.
3. 25 Amp AC Circuit Breaker: Circuit breaker limits
the current that can be delivered through the NEMA
5-20R receptacle to 25 Amps
4. 30 Amp AC Circuit Breaker: Circuit breaker limits
the current that can be delivered through the NEMA
L5-30R receptacle to 30 Amps.
5. Low Oil LED: Indicates low oil level. When the oil
level in the crankcase falls below the safe operating
limit, the low oil level indicator will illuminate and the
generator will automatically shut off the engine.
6. Overload LED: Indicates that the generator is
overloaded.
7. Output Ready LED: Illuminates when the generator
is operating normally. Indicates the generator is
producing electrical power at the receptacles.
2
3
4
15
14
13
12
COMPONENTS
5
6
7 7
8
11
8. Eco Mode: Eco mode minimizes fuel consumption
and noise by adjusting the engine RPM to the
minimum required for the current load.
9. Engine/Fuel Switch: Used to turn fuel valve to the
Run, Choke, or OFF position.
10. Overload Reset: The generator inverter will
automatically switch OFF all AC output to protect
the generator if overloaded or if there is a short
circuit in a connected appliance.
11. Parallel
Operation
Westinghouse
connected for additional power output.
12. CO Sensor indicator lights: The CO Sensor
monitors for the accumulation of poisonous carbon
monoxide gas. If increasing levels of CO gas are
detected, the CO Sensor automatically shuts down
the engine.
13. 120 Volt AC, 30 Amp NEMA L5-30R Receptacle:
Receptacle can supply a maximum of 30 Amps.
14. Ground Terminal: The ground terminal is used to
externally ground the generator.
15. USB Ports: Two-port 5V/2.1A USB outlet. Accepts
Type A USB plugs.
Westinghouse Outdoor Power Equipment, LLC | 9
9
10
Outlets:
A
compatible
Inverter
Generator
can
be