Odor Fade Warning - MrHeater MHI170QFAVT Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ODOR FADE WARNING

WARNING
Asphyxiation Hazard
­ •­Do­not­use­this­heater­for­heating­human­living­quarters.
­ •­Do­not­use­in­unventilated­areas.
­ •­The­flow­of­combustion­and­ventilation­air­must­not­be­obstructed.
­ •­Proper­ventilation­air­must­be­provided­to­support­the­combustion­air­requirements­of­the­heater­being­used.
­ •­Refer­to­the­specification­section­of­the­heater's­manual,­heater­data­plate,­or­contact­the­Factory­to­determine­combustion­air­
ventilation­requirements­of­the­heater.
­ •­Lack­of­proper­ventilation­air­will­lead­to­improper­combustion.
­ •­Improper­combustion­can­lead­to­carbon­monoxide­poisoning­leading­to­serious­injury­or­death.­Symptom­of­carbon­monoxide­
poisoning­can­include­headaches­dizziness­and­difficulty­in­breathing.
FUEL GAS ODOR
LP gas and natural gas have man‑made odorants added
specifically for detection of fuel gas leaks.
If a gas leak occurs you should be able to smell the fuel
gas. Since Propane (LP) is heavier than air you should
smell for the gas odor low to the floor. ANY GAS ODOR
IS YOUR SIGNAL TO GO INTO IMMEDIATE ACTION!
•­
Do­not­take­any­action­that­could­ignite­the­fuel­gas.­Do­­
not­operate­any­electrical­switches.­Do­not­pull­any­power­
supply­or­extension­cords.­Do­not­light­matches­or­any­other­
source­of­flame.­Do­not­use­your­telephone.
•­
Get­everyone­out­of­the­building­and­away­from­the­area­
immediately.
•­
Close­all­propane­(LP)­gas­tank­or­cylinder­fuel­supply­valves,­
or­the­main­fuel­supply­valve­located­at­the­meter­if­you­use­
natural­gas.
•­
Propane­(LP)­gas­is­heavier­than­air­and­may­settle­in­low­
areas.­When­you­have­reason­to­suspect­a­propane­leak,­keep­
out­of­all­low­areas.
•­
Use­your­neighbor's­phone­and­call­your­fuel­gas­supplier­and­
your­fire­department.­Do­not­re-enter­the­building­or­area.
•­
Stay­out­of­the­building­and­away­from­the­area­until­declared­
safe­by­the­firefighters­and­your­fuel­gas­supplier.
•­
FINALLY,­let­the­fuel­gas­service­person­and­the­firefighters­
check­for­escaped­gas.­Have­them­air­out­the­building­and­
area­before­you­return.­Properly­trained­service­people­must­
repair­any­leaks,­check­for­further­leakages,­and­then­relight­
the­appliance­for­you.
ODOR FADING - NO ODOR DETECTED
•­
Some­people­cannot­smell­well.­Some­people­cannot­smell­
the­odor­of­the­man-made­chemical­added­to­propane­(LP)­or­
natural­gas.­You­must­determine­if­you­can­smell­the­odorant­
in­these­fuel­gases.
•­
Learn­to­recognize­the­odor­of­propane­(LP)­gas­and­natural­
gas.­Local­propane­(LP)­gas­dealers­will­be­more­than­happy­
to­give­you­a­scratch­and­sniff­pamphlet.­Use­it­to­become­
familiar­with­the­fuel­gas­odor.
•­
Smoking­can­decrease­your­ability­to­smell.­Being­around­
an­odor­for­a­period­of­time­can­affect­your­sensitivity­to­
that­particular­odor.­Odors­present­in­animal­confinement­
buildings­can­mask­fuel­gas­odor.
Operating Instructions and Owner's Manual
•­
The odorant in propane (LP) gas and natural gas is
colorless and the intensity of its odor can fade under
some circumstances.
•­
If­there­is­an­underground­leak,­the­movement­of­gas­
through­the­soil­can­filter­the­odorant.
•­
Propane­(LP)­gas­odor­may­differ­in­intensity­at­different­
levels.­Since­Propane­(LP)­gas­is­heavier­than­air,­there­may­
be­more­odor­at­lower­levels.
Always be sensitive to the slightest gas odor. If­you­
continue­to­detect­any­gas­odor,­no­matter­how­small,­treat­
it­as­a­serious­leak.­Immediately­go­into­action­as­discussed­
previously.
ATTENTION ‑ CRITICAL POINTS TO
REMEMBER!
•­
Propane (LP) gas has a distinctive odor. Learn to
recognize these odors. (Reference Fuel Gas Odor and
Odor Fading sections above.
•­
Even­If­you­are­not­properly­trained­in­the­service­and­repair­
of­the­heater,­ALWAYS­be­consciously­aware­of­the­odors­of­
propane­(LP)­gas­and­natural­gas.
•­
If­you­have­not­been­properly­trained­in­repair­and­service­
of­propane­(LP)­gas­then­do­not­attempt­to­light­heater,­
perform­service­or­repairs,­or­make­any­adjustments­to­the­
heater­on­the­propane­(LP)­gas­fuel­system.
•­
A­periodic­sniff­test­around­the­heater­or­at­the­heater's­
joints;­i.e.­hose,­connections,­etc.,­is­a­good­safety­practice­
under­any­conditions.­If­you­smell­even­a­small­amount­of­
gas,­CONTACT­YOUR­FUEL­GAS­SUPPLIER­IMMEDIATELY.­DO­
NOT­WAIT!
Heater Elevation Adjustment
This­heater­is­equipped­with­an­elevation­adjustment­panel­located­
at­the­exhaust­end­of­the­control­box.
1.
Do­not­adjust­the­heater­combustion­tube­elevation­while­
heater­is­running­or­hot.­Adjustments­to­elevation­should­only­
be­made­after­the­heater­has­cooled­to­touch.
2.­ To­adjust­the­heater­combustion­tube­elevation,­turn­the­
adjustment­screw­knob­counterclockwise­and­lift­the­
combustion­tube­to­desired­position.
4
Force-Air Propane Construction Heater

Publicidad

Tabla de contenido
loading

Tabla de contenido