Invacare Classic Visco Manual Del Usuario página 3

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
3.3 Symbols on the Product
European
Conformity
Manufacturer
European
representative
Lot number
Machine wash
(maximum
temperature see
label)
Do not iron
Do not bleach
Do not put near
flame
4 Usage
4.1 Safety information
WARNING!
Invacare advise that the patient is assessed by
a trained healthcare professional to ensure the
correct size and seating requirements. This is to
achieve the best pressure and postural care and
that position for the individuals needs are met.
– Always consult a healthcare professional before
using the product.
WARNING!
It is very important for the patient to reposition
themselves, or to be repositioned, on a regular
basis. This relieves pressure which helps prevent
both tissue compression and potential pressure
injury formation.
Skin redness is one clinical indicator for skin
breakdown.
– Regularly inspect/monitor if your skin develops
any redness.
– Immediately contact a healthcare professional,
if your skin develops redness.
1628994-B
Medical Device
Date of
manufacture
Read user manual
Maximum user
weight
Tumble dry low
heat
Do not dry clean
Avoid burning
cigarette
Do not pierce or
cut
IMPORTANT!
Accidental cover damage allows fluid ingress and
staining.
– Do not place sharp objects on the cover.
– When using patient transfer aids, ensure not to
damage the cover. Check for sharp edges or
burrs before use.
– Ensure that the cushion is not jammed or
damaged by sharp edges when used on
wheelchairs.
– Avoid burning cigarettes or open flames near
the cushion.
– If pets are around, ensure that no claws
puncture the cover.
IMPORTANT!
The water resistant cover allows fluids to roll off
the surface, however with sustained periods of
fluid contact the cover may absorb moisture.
– Wipe away any fluid as soon as it is identified.
4.2 Using the cushion
1. Remove all packaging before use.
2. Place the cushion on a wheelchair or chair. Make sure
the carry handle is facing downwards and towards the
rear of the seat.
5 Maintenance
5.1 Inspection
Check cushion (foam and cover) for strike-through (this may
include fluid ingress, stains, rips or damage) after the use of
each patient and on a minimum monthly basis (depending
on which occurs first) by a suitably qualified and competent
person.
Check cushions
1. Unzip the cover completely.
2. Check for any staining on the interior foam.
3. Replace any damaged cover or stained foam and dispose
of as per local authority procedure.
5.2 Cleaning and Disinfection
General Safety Information
CAUTION!
Risk of Contamination
– Take precautions for yourself and use
appropriate protective equipment.
IMPORTANT!
Wrong fluids or methods can harm or damage
the product.
– All cleaning agents and disinfectants used must
be effective, compatible with one another and
must protect the materials they are used to
clean.
– Never use corrosive fluids (alkalines, acid etc.),
abrasive cleaning agents or solvents (cellulose
thinner, acetone etc.). We recommend a mild
detergent.
– Always make sure that the product is completely
dried before taking it into use again.
For cleaning and disinfection in clinical or long-term
care environments, follow your in-house procedures.
3

Publicidad

Tabla de contenido
loading

Tabla de contenido