Starting Screen; Test Screen; Main Screen - voestalpine Böhler URANOS 2700 PMC Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 116
9
Programs
Allows the storage and management of 64 welding
programs which can be personalised by the operator.

3.3 Starting Screen

When switched on, the generator performs a succession of
checks in order to guarantee the correct operation of the system
and of all the devices connected to it.
At this stage the gas test is also carried out to check the proper
connection to the gas supply system.

3.4 Test screen

When the side panel (coil compartment) is open, the welding
operations are inhibited.
The test screen appears on the LCD display.
1
Wire feed
2
Gas test
3
Wire speed
Allows the regulation of the wire feed rate.
Minimum 0.5 m/min, Maximum 22.0 m/min,
Default 1.0m/min
4
Side panel open
5
Heading
Allows the display of certain pieces of important infor-
mation relating to the selected process.

3.5 Main Screen

Allows the control of the system and of the welding process,
showing the main settings.
MMA
TIG DC LIFT START
MIG/MAG
1
Heading
Allows the display of certain pieces of important infor-
mation relating to the selected process:
- The synergic curve selected
1a Type of filler metal
1b Wire diameter
1c Type of gas
- Welding parameters
1d Welding current
1e Part thickness
1f Corner bead
1g Welding voltage
39

Publicidad

Tabla de contenido
loading

Tabla de contenido