Technical Data; Power Requirements - Truper CALA-A2 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Technical data

Code
Description
Voltage
Frequency
Current
Power
Speed
Cutting capacity
Duty cycle
Conductors
Insulating
Laser
WARNING
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
WARNING

Power requirements

WARNING
Tools with double insulation and reiforced insulation are equipped with
a polarized plug (one prong is wider than the other). This plug will only fit in the right way
into a polarized outlet. If the plug cannot be introduced into the outlet, reverse the plug. If
it still doesn't fit, call a qualified electrician to install for you a polarized outlet. Do not alter
the plug in any way. Double insulation eliminates the need of a grounded third power cord
with three prongs or a grounded power connection.
WARNING
When using an extension cable, verify the gauge is enough for the power that your product needs. A lower gauge cable
will cause voltage drop in the line, resulting in power loss and overheating. The following table shows the right size to use
depending on cable's length and the ampere capability shown in the tool's nameplate. When in doubt use the next
higher gauge.
Ampere
Capacity
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
WARNING
When operating power tools outdoors, use a
extension cable labeled "For Outdoors Use". These extensions are specially designed for
operating outdoors and reduce the risk of electric shock.
30 minutes work per 15 minutes idle. Maximum 3 hours per day.
Class II
Class II | Source: laser diode | Power: 1,0 mW (max) | Wave length: 680 nm
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
Before gaining access to the terminals all power sources should be disconnected.
Number of
Conductors
3 (one grounded)
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE-2006
CALA-A2
16674
Jig saw
120 V
60 Hz
5,9 A
0.9 Hp
0 - 3 000 strokes / min
Wood 3.14" | Metal 0.39"
18 AWG x 2C with insulating temperature of 221 °F
IP Grade
Power Cord Grips: Type Y.
Build Quality: Reinforced Insulation.
Thermal Insulation on Motor Winding: Class B.
Extension gauge
from 5.9´ to 49.2´
18 AWG( * )
16 AWG
14 AWG
8 AWG
IP20
Authorized Service Center.
|
higher than 49.2´
16 AWG
14 AWG
12 AWG
6 AWG
grounded
ENGLISH
3