Technical Data; Power Requirements - Truper SCI-10 Manual De Instrucciones

Sierra de cinta
Ocultar thumbs Ver también para SCI-10:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Technical Data

Code
Description
Cutting Band
Voltage
Frequency
Current
Power
Band Speed
Duty cycle
Conductors
Insulating
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING

Power Requirements

WARNING
The tool shall be grounded while being used to prevent electric shock.
• Connect the plug into a properly grounded electric contact as shown in
example A. Not all contacts or plugs are properly grounded. In doubt please
verify with a qualified electrician.
• If the electric contact to be used with the tool has two poles (2 orifices), DO
NOT REMOVE OR ALTER THE GROUND CONDUCTOR IN THE PLUG. Use a
temporary adaptor as shown in example B, and always connect the ground
conducting lug as indicated.
CAUTION
When using an extension cord, verify the gauge is enough for
the power that your product needs. A lower gauge cable will cause voltage drop
in the line, resulting in power loss and overheating. The following table shows the
right size to use depending on cord´s length and the ampere capability shown in
the tool's nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
From 0 and up to 10 A
From 10 and up to 13 A
From 13 and up to 15 A
From 15 and up to 20 A
WARNING
When operating power tools outdoors, use a
Outdoors Use". These extensions are especially designed for operating outdoors and reduce the risk of electric
shock.
60 minutes work and 30 minutes idle. Maximum 6 hours per day.
18 AWG x 3C with insulating temperature of 221°F
Power Cord Grips used in this product: Type "Y".
Tool Build Quality: Basic insulation
Thermal insulation on motor winding: Class B
Number of
Conductors
from 5,9' to 49,2'
3 (one grounded)
SCI-10
16277
Band Saw
Width: 1/4" - 1/2"
Length: 5.6'
120 V
/
220 V
60 Hz
3.2 A / 1.7 A
1/3 HP
2788 ft/min
Clase I
Authorized Service Center.
CAUTION
Extension Gauge
|
higher than 49,2'
18 AWG
16 AWG
14 AWG
8 AWG
grounded extension cable labeled "For
A
B
16 AWG
14 AWG
12 AWG
6 AWG
3
ENGLISH